Page 1
USER MANUAL and INSTALLATION GUIDE INDOOR UNIT OUTDOOR UNIT ECOLIGHT 9000 UI ECOLIGHT 9000 UE ECOLIGHT 12000 UI ECOLIGHT 12000 UE ECOLIGHT 18000 UI ECOLIGHT 18000 UE ECOLIGHT 24000 UI ECOLIGHT 24000 UE Please read this manual carefully before installing and using the air conditioner, and retain for future reference.
Contents Information for use The Refrigerant Precautions for use Description of components Guide to the remote control and display Remote control buttons Getting to know the display icons Getting to know the remote control buttons Getting to know the button combination functions Operating guide ...
Appliance filled with flammable gas R32. Before using the appliance, read the owner’s manual. Before installing the appliance, read the installation manual. Before repairing the appliance, read the service manual. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
INFORMATION FOR USE Precautions for use WARNING This product is not a toy. Children of less than 3 years should be kept away unless continuously supervised. This device is not intended for persons (including children aged from 8 years and above) with reduced physical, sensory or mental capabilities, or without the necessary experience and knowledge, unless they have received the necessary supervision or instruction concerning use of the appliance by a person...
Page 5
Always install a circuit breaker. Otherwise, a fault may occur. The unit must be installed and serviced by a qualified technician. Otherwise, there is a risk of damage or personal injury. WARNING In case of smoke or burning smell, ...
Description of components Indoor unit ingresso aria air inlet pannellino panel filtro filter Tasto ausiliario auxiliary button Deflettore orizzontale horizontal flap uscitadell’aria air outlet Spia alimentazione power indicator Finestrella ricevitore receiver window Spia temperatura temperature indicator telecomando remote control The display may vary from the graphic above. Please refer to the purchased product for the actual display content and positions) V 11/17...
Outdoor unit Unità esterna ingresso aria impugnatura uscita aria Unitàesterna Outdoor unit ingresso aria air inlet impugnatura handle uscita aria air outlet GUIDE TO THE REMOTE CONTROL AND DISPLAY Remote control buttons On/Off button Mode button Fan button ▲/ button Swing button Sleep button Temp button Turbo button I Feel button Timer button...
Getting to know the display icons Temp. display type :Set temp. :Indoor ambient temp. :Outdoor ambient temp. Turbo mode Set fan speed Send signal Operation mode Child lock health function Auto mode ventilation operation Cool mode 8℃ heating function Dry mode Set temperature Sleep mode Fan mode...
Page 9
button to adjust the fan speed. Pressing the "SWING" button will allow you to adjust the angle of airflow. When you select dry mode, the air conditioner will run at low speed in dry mode. The indicator will illuminate on the display. The fan speed cannot be adjusted in this mode. Pressing the "SWING"...
Page 10
nessuna visualizzazione Nessuna visualizzazione no display • When you select or “no display” with the remote control, the set temperature will appear on the indoor unit's display. • When you select with the remote control, the indoor ambient temperature will appear on the indoor unit's display.
Getting to know the button combination functions Energy saving function In cool mode, press the TEMP and CLOCK buttons simultaneously to start or stop the energy saving function. When you start the energy saving function, "SE" will appear on the remote control display and the air conditioner will automatically adjust the set temperature according to the factory settings to achieve the best energy-saving effect.
Optional Operations 1. Press the SLEEP button to set the function sleep 2. Press the timer ON/ timer OFF button to set the timer ON or timer OFF 3. Press the LIGHT button to check the switching on or off of the different parts of the display (this function may not be possible for some units) 4.
Emergency operation In the event of loss or failure of the remote control, use the emergency button located under the indoor unit's front panel to turn the air conditioner on or off. The unit will operate in automatic mode on start-up. pannellino tasto ausiliario pannellino ...
Do not use a hairdryer to dry the filters; the heat can cause damage and warping. Before-use checks 1. Check that the air inlet and outlet are free of obstructions. 2. Check that the circuit breaker, plug and socket are in good working order. 3.
fuse blown? by a qualified technician. Is the wiring faulty? Have it replaced by a qualified technician. Was the unit restarted immediately after Wait 3 minutes and then restart the unit. shutdown? Is the setting on the remote control Reset the function. correct? The indoor unit's Is the indoor temperature and humidity...
Page 16
Can be eliminated by turning the unit off and on again. Otherwise, contact a qualified technician for assistance. Contact a qualified technician for assistance. Contact a qualified technician for assistance. Contact a qualified technician for assistance. Contact a qualified technician for assistance. It can be eliminated switching off the unit and switching it back on.
INSTALLATION WARNINGS WARNING: Make sure that the power supply is disconnected before carrying out any work on the unit. WARNING: Wear appropriate personal protective equipment before carrying out any work on the unit. WARNING: The appliance must be reinstalled in accordance with national system regulations.
Electrical connection requirements Safety precautions 1. Electrical safety standards must be met when installing the unit. 2. Use a power supply circuit and circuit breaker that comply with local safety regulations. 3. Make sure that the power supply matches the requirements of the air conditioner. An unstable power supply or incorrect wiring may result in a fault.
Page 20
Step three: drill the hole for the piping Select the position for the piping hole according to the direction of the outlet pipe. The piping hole must be slightly lower than the wall-installation frame, as shown below. Drill a piping hole of diameter at the chosen location for the outlet pipe.
Page 22
3. Remove the cable clip. Connect the power cable to the terminal block according to colour. Tighten the screw and secure the power cable with the clip. Note: the link card is only for reference, plase take into consideration the actual one. blu ...
Step nine: hang the indoor unit 1. Insert the bound pipes into the wall pipe and route them through the hole in the wall. 2. Hang the indoor unit on the wall-installation plate. 3. Fill the gap between the pipes and the hole in the wall with sealant. 4.
Page 24
fori piedini foro di chassis scarico giunto di tubo di scarico scarico esterno fori piedini foro di scarico drain hole tubo di scarico drain pipe chassis chassis giunto di scaricoesterno outdoor drain joint Fori piedini foot holes Step four: connect the indoor and outdoor pipes 1. Remove the screw on the right-hand handle 3.
Page 25
2. Secure the power cable and the signal control cable with the clip (only for cooling and heating units). N.B.: • Once you have tightened the screw, pull on the power cable gently to check it is secure. • Never cut the power cable to extend or reduce the distance. Step six: tidy up the pipes 1.
Vacuum pump Using the vacuum pump Remove the valve caps of the liquid valve and valvola del liquido piezometro gas valve and remove the nut of the valvola del gas refrigerant charge port. apertura carica cappuccio Connect the piezometer charge pipe to the refrigerante valvola refrigerant charge bore of the gas valve.
Have the dust and other particles produced during Risk of malfunction or damage to components. installation been removed? Are the gas valve and liquid valve of the connecting tube The cooling (heating) capacity may be insufficient. fully open? The entrance and exit of the pipe holes have been Risk of condensation and dripping water.
Safety operation of flammable refrigerant Qualification requirement for installation and maintenance All workers who engage with the refrigeration system should bear the valid certification awarded by the authoritative organization, and the qualification recognized by the industry for dealing with the refrigeration system. ...
Filling the refrigerator circuit Use refrigerant filling appliances specialized for R32. Make sure that different kinds of refrigerant don’t contaminate one another. The refrigerant tank should be kept upright when filling with the refrigerant. Stick the label on the system after filling is finished. ...
Page 30
6. Inspection tubo Check the quality of the expanded port. limatrice defective, expand the port again following the procedure described above. verso il basso tubo pipe limatrice file superficie liscia verso il basso downwards allargamento imperfetto 3. Secure an insulating tube 4.
Page 31
REGULATION (EU) No. 517/2014 - F-GAS The unit contains R32, a fluorinated greenhouse gas with global warming potential (GWP) = 675. Do not release R32 into the atmosphere. ECOLIGHT 9000 UE - Kg. 0,6 = 0.405 Tonn CO equiv. ECOLIGHT 12000 UE - Kg. 0,65 = 0,439Tonn CO equiv. ECOLIGHT 18000 UE - Kg. 0,77 = 0,520 Tonn CO equiv.