Argo Ulisse 10 AUR101CL Technical Data & Service Manual page 28

Room air conditioner with remote condenser
Table of Contents

Advertisement

(4) Check fuse on PCB Ass'y in indoor unit.
Check fuse on PCB Ass'y in indoor unit
for continuity.
If fuse blows, there is a
possibility of short circuit.
Measure resistance of indoor fan motor
winding (FMI).
(5) Check setting temperature.
COOL
Is room temperature too low?
NO
Try to lower setting temperature by
temperature setting button
Outdoor unit still does
not run
Try to use another remote
control unit
OK
Remote control unit is defective
OK
PCB Ass'y in indoor unit is defective.
Is room temperature too high?
Try to raise setting temperature by
temperature setting button
Try to use another remote
control unit
Remote control unit is defective
28
HEAT
NO
Outdoor unit still does
not run
OK

Advertisement

Table of Contents
loading

Table of Contents