Kenwood TK-5710 Service Manual page 68

Vhf apco p25 transceiver
Hide thumbs Also See for TK-5710:
Table of Contents

Advertisement

(
)
TK-5710
B
Item
6. Sensitivity
1) CH-Sig:1-1
Check
SSG output:-117dBm(0.32µV) AF VTVM
•Wide
(MOD:1kHz/±3kHz)
2) CH-Sig:2-1
3) CH-Sig:3-1
•Narrow
4) CH-Sig:1-1
SSG output:-117dBm(0.32µV)
(MOD:1kHz/±1.5kHz)
5) CH-Sig:2-1
6) CH-Sig:3-1
7. Squelch
1) Adj item:[W SQOW]
(Threshold)
Adjust:[***]
adjust
2) Adj item:[WL SQOW]t
•Wide
[WC SQOW]t[WH SQOW]
Adjust:[***]
SSG output:12dB SINAD level -3dB
(MOD:1kHz/±3kHz)
•Narrow
3) Adj item:[N SQON]
Adjust:[***]
SSG output:12dB SINAD level -3dB
(MOD:1kHz/±1.5kHz)
68
(
)
/5710H
B
ADJUSTMENT
Measurement
Condition
Test-
equipment
SSG
Oscilloscope
Unit
Terminal
Unit
Rear
ANT
panel
EXT.SP
Front
[PF5]
panel
Adjustment
Specifications/Remarks
Parts
Method
Check
12dB SINAD or more
After input
After adjusting SQL,
signal from SSG, check SQL open/close.
press [PF5] key. [Panel test mode]
That numeric
1) CH-Sig:1-1
will be stored
SSG 12dB SINAD or
in memory.
SSG -130dBm(0.07µV):Close
2) CH-Sig:2-1
SSG 12dB SINAD or
SSG -130dBm(0.07µV):Close
3) CH-Sig:3-1
SSG 12dB SINAD or
SSG -130dBm(0.07µV):Close
After adjusting SQL,
check SQL open/Close.
[Panel test mode]
1) CH-Sig:1-1
SSG 12dB SINAD or
SSG -130dBm(0.07µV):Close
2) CH-Sig:2-1
SSG 12dB SINAD or
SSG -130dBm(0.07µV):Close
3) CH-Sig:2-1
SSG 12dB SINAD or
SSG -130dBm(0.07µV):Close
less:Open
less:Open
less:Open
less:Open
less:Open
less:Open

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-5710bTk-5710hTk-5710hb

Table of Contents