Setup Menu
Setup menu item details
MODE Operating Mode
The SV controllers feature four different operating modes that effect demand heating
and filtration behaviour (refer table below).
Item
Mode
Notes
*
NORM
Normal
Normal operation for demand heating and filtration
ECON
Economy Demand heating can only occur when filtration pump is running
AWAY
Away
Demand heating is DISABLED. Filtration is fixed at 1 hour
per day (the keypad will scroll "AWAY MODE" every 60 secs)
WEEK
Week
Monday to Thursday: Demand heating is DISABLED and filtration
fixed at 1 hour per day. Friday to Sunday: Normal Operation
* Default Setting = NORM
FILT
Filtration (hours per day)
Automatic filtration is provided to ensure that the pool water is filtered for at least a
minimum time each day after considering how often the pool has had manual use or
how long the filtration pump runs for water temperature maintenance. All time spent
running the pump under normal operation (manual use, water temperature
maintenance, sanitisation cycles) will be taken into account and where required the
pump will run for additional periods throughout the day to maintain the minimum level
of daily filtration as specified by the user. SV controllers support two different types of
pump for heating and filtration. The default filtration hours and adjustment limits differ
for each pump type as follows:
Small circ pump
Minimum filtration hrs p/day
Maximum filtration hrs p/day
Default filtration hrs p/day
SV Series Spa Controls
Jet pump
(2A or less)
(2spd or 1spd)
1
1
24
8
4
3
F.CYC Filtration Cycle Blocks (how often filtration cycles occur)
This setting allows the user to adjust the frequency of the filtration cycle(s). The user can
set filtration blocks to occur every hour, right down to once a day, or somewhere in
between.
Select filtration to occur every 1 / 2 / 3 / 4 / 6 / 8 / 12 or 24 hours
Default setting = 4 hrs (i.e. a filtration block will run every 4 hours)
SNZE
Sleep Timers
Programmable feature to disable automatic heating and filtration to stop all spa activity
during certain times of day or night (refer detailed notes on page 24).
Default Setting = Sleep Timer 1 (Sat – Fri; Sleep period 22:00 – 07:00)
P.SAV Power Save Setting (off peak filtration and heating)
Lower daily operating costs by programming either filtration only (LOW), or both
filtration and heating (HIGH) to occur during off-peak power periods when the electricity
rates are cheaper (refer detailed notes on page 25).
The setting choices are: OFF / LOW
Default Setting = OFF
W.CLN Automatic Daily Sanitise Cycle Run Time
SV controllers are automatically programmed to activate a 10 minute daily sanitisation
cycle at a given time, where each pump/blower is operated to purge pipe work whilst
operating the filtration pump. This setting allows adjustment of the start time of the
automatic daily sanitise cycle.
Setting ranges from 00:00 to 23:59
Default = 09:00 (9AM)
22
/ HIGH
(off-peak filtration)
(off-peak filtration & heating)