Cooling System
Seawater Inlet Hose
•
A reinforced hose capable of supporting 10 in. Hg vacuum must be used to prevent the
seawater inlet hose from collapsing from pump suction.
•
The hose should be oil and seawater resistant.
•
Use the shortest hose length possible with the least number of bends to minimize
restriction.
•
All connections must be secured with a hose clamp.
•
Fasten hose as appropriate to maintain proper routing and to prevent chafing or contact
with other moving parts.
Typical composite seawater pickup pump
Page 7A-4
a
7638
a -
Seawater inlet hose connection
a
Typical brass seawater pickup pump
90-863758060 AUGUST 2006