Exhaust System
•
Install risers or lower the muffler if necessary to meet minimum exhaust elbow height.
•
The water line inside the muffler is the beginning measurement point to determine the
correct elbow height.
Collector and Water Lift Muffler
b
a
S‑pipe Used With Water Lift Muffler
a
Page 6A-14
e f
c
d
a -
Water line
b -
Siphon break (vacuum valve) Must
be installed in cooling water circuit
if exhaust elbows are at or below
water level. Refer to muffler
manufacturing recommendations.
c -
Exhaust back pressure check
point
d -
Resonator
e -
46 cm (18 in.) minimum between
exhaust elbow and collector
f -
10° downward slope minimum
a -
Water line
b -
Minimum exhaust elbow height
with maximum load
g
i
Typical
g -
3° downward slope minimum
h -
Collector
i -
Minimum exhaust elbow height with
maximum load
j -
Drain fitting
k -
External flappers
b
c
c -
Drain plug
k
j
15636
7556
90-863758060 AUGUST 2006