Specifications; Standard Equipment; Optional Extras; Safety Notes - Electrolux GSG 580 User's Installation And Servicing Manual

Gas supergrill/jet grill
Table of Contents

Advertisement

SPECIFICATIONS

Output
Grilling
(227gm steaks)
Toasting
Dimensions cm
Overall (wxdxh)
Heat Input
Btu/hkW (Natural Gas)
Net Weigh kg
850
651
GENERAL
The 600/800 GAS SUPERGRILL can be supplied for use
with either Natural Gas or LP (propane or butane). Details
will be found on the Data Plate fixed to the appliance. A
conversion kit is required to change from one gas supply to
the other. Supplied as kit at installation.

STANDARD EQUIPMENT

1. Toasting rack with crumb
2. Brander plate, frame and drip trough.

OPTIONAL EXTRAS

Bench stand
Wall bracket
Floor stand
800 Model
100/h
400/h
850x54x54
42,000/12.4
50
540
84
603
55
10
330
10
FIXING POINTS
Dimension in mm.
Figure 1.
Additional Branding plates
GAS DATA
MODEL
900 SUPERGRILL
900 JETGRILL
900 SUPERGRILL
900 JETGRILL
BURNER AND INJECTOR RATINGS
MAIN BURNER
MODEL
900
900
PILOT BURNER
MODEL
900
900
APPLIANCE PRESSURE
MODEL
900
900
900
BURNER RATING
MODEL
900
900
TOTAL RATING
MODEL
900
900

SAFETY NOTES

1. It is the law that all gas appliances are installed by
competent person in accordance with the requirements of
the Gas Safety (Installation and Use) Regulations. Failure
to comply and install appliances incorrectly could lead to
prosecution. The Confederation for Resgistration of Gas
Installers (CORGI) requires its members to work to
recognised standards.
2. The installation of this appliance must be carried out in
accordance with these instructions, and meet with the
requirements of the Gas Safety Regulations, the Fire
Precautions Act, Local and National Building Regulations
and the recommendations contained in the revelant British
Standards Codes of Practice. The requirements of the
Health and Safety at Work Acts and Hygiene must be
observed.
3. This appliance is designed for commercial purposes only,
and must be operated by trained personnel.
4. This appliance is provided with an equipotential screw
fixing if required.
2
TYPE OF GAS
MODEL No
NATURAL GAS
GSG 580NG
NATURAL GAS
JG/G 580 NG
LPG
GSG 580LP
LPG
JG/G 580 LP
TYPE OF GAS
INJECTOR SIZE
Natural Gas
640 AMAL
Butane/Propane
200 AMAL
TYPE OF GAS
INJECTOR SIZE
Natural Gas
Butane/Propane
TYPE OF GAS
PRESSURE
Butane
28mbar(11.2"WG)
Propane
37mbar(14.8"WG)
NG
20 mbar (8"wg)
TYPE OF GAS
PRESSURE
Natural Gas
6.2kW/21,000Btu/h
Butane/Propane
6.2kW/21,000Btu/h
TYPE OF GAS
RATING
Natural Gas
12,4kW/42,000Btu/h
Butane/Propane
12,4kW/42,000Btu/h
N22
N14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jg/g580Jg580G580