  • Page 1 200100222 ISSUE 02/01 GAS SUPERGRILL/JET GRILL USER’S INSTALLATION AND SERVICING MANUAL Electrolux Foodservice Zanussi Professional PNC: 283581; 283580 Model: GSG 580; JG/G580...
  • Page 2: Specifications

    Additional Branding plates SPECIFICATIONS Output 800 Model GAS DATA Grilling 100/h (227gm steaks) MODEL TYPE OF GAS MODEL No Toasting 400/h 900 SUPERGRILL NATURAL GAS GSG 580NG 900 JETGRILL NATURAL GAS JG/G 580 NG Dimensions cm 900 SUPERGRILL GSG 580LP Overall (wxdxh) 850x54x54 900 JETGRILL...
  • Page 3: Gas Connection

    5. It is the responsability of the kitchen supervisor to warn 2. Ensure that the area where the appliance is to stand is users of this appliance to wear suitable protective level, and is capable of supporting the weight of the clothing.
  • Page 4: Lighting Procedure

    14. Remove the pressure test gauge and refit the Pressure Test Once the pilot been established, the Rear Burner can be point Sealing Screw. turned on. 15. Turn ON the gas supply at the Isolating Tap and leak-test Turn the Main Control Knob anti-clockwise to the LOW the Pressure Test Point Sealing Screw.
  • Page 5: Maintenance

    ALWAYS FIT THE DRIP/BASTING TROUGH taken to avoid damaging the ceramic plaques of the burners. MOUNTED ON THE FRONT BASE OF THE GRILL when Any deposits left on plaques will quickly burn off by using the Brander, otherwise grease and juices from the themselves.
  • Page 6: Fault Finding

    It is recommended that the servicing of this appliance should number of the component required. be carried out under a service contract provided by Electrolux FAULT FINDING SYMPTON POSSIBLE CAUSE...
  • Page 7 Replace in a reverse sequence ensuring that the panel fits Turn the gas tap to the LOW setting and check the flame correctly over the gas pipes and cable going into the does not extinguish. control compartment. C. R.H. OUTER SIDE PANEL REMOVE/REPLACE (figure 3) G.
  • Page 8: Piezo Igniter

    Unfasten two screws (9) and remove the pilot protection bracket (10) from inside the grilling compartment. Unscrew nut (4) and ease tube (5) away from burner. NOTE: the injector (6) is secured within the tube of the pilot burner and may have to be extracted by carefully prising around its edge.
  • Page 9: Main Burner Injector

    Disconnect ignition lead (1) from electrode (3). Unfasten two screws(11) and remove the burner assembly from the appliance. Remove the ignition electrode (3) from the assembly. Inspect and renew if necessary. Fit new pilot burner by reversing the above sequence. Turn on the gas supply to the appliance and light the pilot burner, ensuring that the igniter and thermocouple operate correctly.
  • Page 12: Spare Part List

    SPARE PART LIST CODE: 283580, 283581 MODEL: GSG-580, JG/G-580 CODE DESCRIPCION UDS/A 550000400 PANEL DE BASE BASE PANEL 550000600 CONJ. PANEL INTERIOR IZQUIERDO INNER LEFT HAND PANEL 550000700 CONJ. PANEL INTERIOR DERECHO INNER RIGHT HAND PANEL 550003200 PANEL POSTERIOR BASCK PANEL 550000900 LATERAL IZQUIERDO LEFT HAND OUTER PANEL 550001600 LATERAL DERECHO...
  • Page 13 SXJ219 MANGUITO ADAPTADOR 10 R-3/8" COUPLING 10 R=3/8" SXJ222 CODO+BICONO+TUERCA M-10X1 D=6 ELBOW + BICONE + NUT D=6 550002700 TORNILLO FIJACIÓN FIXING SCREW 514804200 INYECTOR D.2,00 NG* INJECTOR MAIN BURNER NG* D 2.00 514803700 INYECTOR D.1,20 GLP* INJECTOR MAIN BURNER LPG* D 1.20 514805300 OBTURADOR D.1,6 BYPASS ORIFICE LPG* 514805100 OBTURADOR D.2,50...