Kenwood NX-700 Service Manual page 55

Vhf digital transceiver
Hide thumbs Also See for NX-700:
Table of Contents

Advertisement

Item
Panel test mode
[Wide]
1) Adj item: [Aw ADEV]
Adjust: [✳✳✳✳]
2) Adj item:
[AwL ADEV]→
[AwL' ADEV]→
[AwC ADEV]→
[NvH' NDEV]→
[NvH NDEV]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
*3: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 57.
Analog deviation adjustment (Narrow/Wide) is common with the adjustment of all analog signaling.
8. QT
1) Adj item: [An QT]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw QT]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
9. DQT
1) Adj item: [An DQT]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw DQT]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Maximum
Deviation
Deviation (Analog
meter
Wide)]
Oscilloscope
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [QT
Deviation
Deviation (Narrow)]
meter
Deviation meter
Oscilloscope
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [QT
Deviation (Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [DQT
Deviation (Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [DQT
Deviation (Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
ANT
ANT
NX-700/700H
Adjustment
Parts
Method
[Panel
Write the same
4150~4250Hz
tuning
adjustment value of
mode]
"NXDN Deviation
[PC test mode]
[ ],[ ]
[Narrow]" for each
Press [Apply All]
adjustment point.
button to store the
[PC test
Transmit at each
adjustment value
mode]
adjustment point and
after all adjustment
[ ],[ ]
check that the Analog
point was adjusted.
deviation is between
4150Hz and 4250Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press
[Transmit] button
[Panel
Write the value as
0.30~0.40kHz
tuning
followings.
mode]
513 (Reference
[ ],[ ]
value)
[PC test
mode]
[ ],[ ]
0.70~0.80kHz
Write the value as
0.30~0.40kHz
followings.
430 (Reference
value)
0.70~0.80kHz
Specifi cations /
Remarks
55