Room Air Conditioner
KWH22CRF, KWH22HRF
KWH27CRF, KWH27HRF
KWH39CRF, KWH39HRF
KWH52CRF, KWH52HRF
KWH60CRF, KWH60HRF
Refrigerant R32
CARE & USE
Australians love
a Kelvinator

Advertisement

loading
Need help?

Need help?

Do you have a question about the KWH22CRF and is the answer not in the manual?

Questions and answers

Lynn Myra McElroy
February 23, 2025

Is there a drain plug on the Kelvinator Air Conditioner- Model KWH39HRF . There is no water dripping out of the drain pan tube, even though there's residual water in the base pan of the unit a day later.

User image 67ba9b485ad8a
1 comments:
Mr. Anderson
February 23, 2025

Yes, the Kelvinator Air Conditioner model KWH39HRF has a drain plug. The manual mentions that the drain plug can be removed to drain water to a specific location and/or reduce noise, but its removal may reduce performance.

This answer is automatically generated

Geoffrey Smith
January 19, 2025

I might have asked this question, what year was the KWH 52HRF AIR CONDITIONER MADE

Geoffrey Smith
January 19, 2025

What tear was the Kelvinator KWF52HRF Window installed made

Summary of Contents for Kelvinator KWH22CRF

  • Page 1 Window Wall (Electronic) Room Air Conditioner KWH22CRF, KWH22HRF KWH27CRF, KWH27HRF KWH39CRF, KWH39HRF KWH52CRF, KWH52HRF KWH60CRF, KWH60HRF Refrigerant R32 CARE & USE Australians love a Kelvinator...
  • Page 2: Table Of Contents

    This unit uses refrigerant R32 and must be disposed of your ability to make a claim under the Kelvinator by a licensed refrigeration mechanic with knowledge of manufacturer’s warranty provided with your product.
  • Page 3: Safety Precautions

    Ventilate room before operating air conditioner if there is a gas leakage from another appliance. It may cause explosion, fire and burns. Do not disassemble or modify unit. It may cause failure and electric shock. Kelvinator Air Conditioning Important safety instructions 3...
  • Page 4: Prior To Operation

    Use caution when unpacking and installing. Sharp edges could cause injury. Do not drink water drained from air conditioner. It contains contaminants and could make you sick. 4 prior to operation/operating temperature Kelvinator Air Conditioning...
  • Page 5: Unit Parts Identi Cation

    To open the vent, set the lever to the right position. power cord To close it, set the lever in the left position. wall outlet E- earthwire, yellow/green air break switch N- neutral wire, blue A - active wire, brown Kelvinator Air Conditioning unit parts iden cation/operation instructions 5...
  • Page 6 Press the "SWING" keypad to activate the automatic air swing (oscillation) feature. The vertical louvers will oscillate back and forth (side to side) automatically sweeping air around for comfortable cooling/heating. To stop the air swing feature, pressing the "SWING" keypad again. 6 operating instructions Kelvinator Air Conditioning...
  • Page 7 (as depicted inside the battery chamber). Re-install lower battery cover. If the remote control is not being used for extended time periods, (vacation, off season) the batteries should be removed from the remote control unit. Kelvinator Air Conditioning remote control features 7...
  • Page 8 OFF; Under OFF status, press the button to set timer ON. Time setting range is 0.5~24hours. Auto: Press the "AUTO" button to active the "AUTO" function and the unit will be running according to room temperature. 8 remote control features Kelvinator Air Conditioning...
  • Page 9: Maintenance

    During a power failure, the air conditioner will stop DRAIN RUBBER JOINT PLUG SEAL completely. When the power is restored, the air conditioner will start automatically with all the previous settings preserved in the memory. DRAIN RUBBER JOINT PLUG SEAL Kelvinator Air Conditioning remote control features/installation instructions 9...
  • Page 10: Installation Instructions

    100mm minimum and rodents. AIR OUT Over Over Note: Unit may be supported by a solid frame from below or 150mm 150mm OPTION B OPTION A by a hanger from a solid overhead support. 10 installation instructions Kelvinator Air Conditioning...
  • Page 11 (See Fig. 2). Hang the front panel on the frame's top edge, then press the front panel into the frame edges until you hear clicks. Fig. 3 Fig. 4 Fig. 5 Fig. 6 Kelvinator Air Conditioning installation instructions 11...
  • Page 12: Troubleshooting

    See Air Conditioner Freezing have iced up. Up below. Ice blocks the air flow and stops the air Set the fan at MED or HIGH conditioner conditioner until the ice melts. freezing up from cooling the room. 12 troubleshooting Kelvinator Air Conditioning...
  • Page 13 Notes Kelvinator Air Conditioning Specifications 13...
  • Page 14 Notes 14 notes Kelvinator Air Conditioning...
  • Page 15 Kelvinator Air Conditioning warranty 15...
  • Page 16 Customer Care team or visit our website. telephone: 13 13 49 email: customercare@electrolux.com.au web: kelvinator.com.au Kelvinator. We are part of the Electrolux family. Share more of our thinking at www.electrolux.com.au P/No. 1452635 66129933579 © 2019 Electrolux Home Products Pty Ltd ABN 51 004 762 341 KMAN_WWE_Factory_Jun20...