7-channel analog input interface
Table of Contents

Advertisement

GAIN
FULL SCALE
LSB
RMS NOISE*
STD DEVIATION
OFFSET AFTER
CALIBRATION
(WORST CASE)**
ACCURACY AFTER
CALIBRATION
(WORST CASE)**
INPUT
AMPLIFIER
SLEW RATE
MAX. SAMPLE
RATE (ACHOSS
CHANNELS)
MAX. SAMPLE
RATE (ON A
SINGLE CHANNEL)
98640A Analog Input Interface
Table
1-1
SAMPLING CHARACTERISTICS
1
8
64
512
±10V
±1.25V
±156mV
±19.5mV
2. 44mV
305uV
38.1UV
4. 77uV
5mV
600uv
lOOUV
18uv
±7.3mV
±915uV
±152UV
±24uv
±18mV
±3mV
±250uV
±75uV
400mV/usec
50mV/usec
4mV/usec
40uV/usec
20k/sec
20k/sec
14k/sec
lk/sec
55k/sec
55k/sec
55k/sec
55k/sec
*
By averaging readings noise can be reduced to less than one least significant bit (Isb).
**
These figures are based on an HP 98640A whose data were processed and controlled
by routines from the HP 98645A Measurement Library. The accuracy figures show
the worst case affects of noise after the library's noise reduction routine is used.