other than instructed in this manual.
D) Burning of anything other than the type of
gas approved for use in this gas appliance.
The installation must conform with local
codes or, in the absence of local codes, with
the current National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
This fireplace complies with the National
Safety Standards and is listed and tested by
PFS Corporation to ANSI Z21.50/CSA 2.22
standard as vented gas fireplace.
WARNING: Installation of
this appliance should be done
by a qualified service person
well trained in the installation
of such appliances. You will
also need a building permit
from your local Building and
Safety Commissioner before
installing this appliance; oth-
erwise your insurance co. may
not cover this appliance.
To determine the safest and most efficient
location for your appliance, you must take
into consideration the following guidelines:
1. The location must allow for proper clear-
ances (see Clearances, page 7).
2. Consider a location where heat output
would not be affected by drafts, air con-
ditioning ducts, windows or doors.
3. A location that avoids the cutting of joists
or roof rafters will make installation easier.
Figure 1 shows a plan view of a few com-
mon locations.
Flush installations are recommended where
living space is limited or at a premium and
since the space required to enclose the ap-
pliance would be located beyond an outside
wall, this would also reduce the cutting of
joists, roof rafters and such. Check local
codes for any restrictions.
Projected installations can extend any
distance into the room. A projection may
be ideal for a new addition on an existing,
finished wall.
126736-01B
INTRODUCTION
Continued

SELECTING LOCATION

www.SuperiorFireplaces.US.com
NOTICE: Decorative product
not for use as a heating ap-
pliance.
The appliance and it's individual shutoff valve
must be disconnected from gas supply piping
system during any pressure testing of that
system at test pressures in excess of 1/2 psi
(3.5 kPa).
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
For the purpose of input adjustment two
pressure taps (for IN and OUT pressures)
are provided on the gas control valve for test
gauge connections to the appliance.
CAUTION: Do not
connect appliance before
pressure testing gas piping.
Damage to gas valve
may result and an unsafe
condition may be caused.
Corner installations make use of space
that may not normally be used and provides
a wider and more efficient range for radiant
heat transference.
Internal wall installations provide a discreet
option for room separation and can also be
ideal as an addition to an existing wall.
INTERNAL WALL
INSTALLATION
FULL
PROJECTION
INSTALLATION
Figure 1 - Possible Locations for
Installing Appliance
CORNER
INSTALLATION
FLUSH
INSTALLATION
5