Superior BRT40STTMN Installation And Operation Instructions Manual

Brt40st b-vent gas fireplaces

Advertisement

Quick Links

P/N 900301-00 REV. C 05/2016
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900301-02.
P900301-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Decorative Product: Not for use as a heating
appliance.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
BRT40ST B-Vent Gas Fireplaces
Models
PFS
®
C
US
Report No. F14-172
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
NOTICE: Fireplace is not to be operated by a
thermostat.
BRT40STTMN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.

Advertisement

Table of Contents
loading

Summary of Contents for Superior BRT40STTMN

  • Page 1 P/N 900301-00 REV. C 05/2016 Ce manuel est disponible en francais, simplement Models en faire la demande. Numéro de la pièce 900301-02. ® BRT40STTMN Report No. F14-172 P900301-00 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil.
  • Page 2: Safety And Your Fireplace

    Innovative Hearth Products General Information BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent EXTRÊMEMENT CHAUDES ! EXTREMELY HOT! MUY CALIENTES! ...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 TABLE OF CONTENTS PACKAGING WARNING Safety and Your Fireplace ....Page 2 The assembled vented gas fireplace is pack- Young children should be care- Packaging .........Page 4 aged with: fully supervised when they are Introduction ........Page 4 1 - One log set located within the firebox.
  • Page 5 Innovative Hearth Products General Information BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 These appliances comply with National Safety WARNING WARNING Standards and are tested and listed by PFS (Report No. F14-172) to ANSI Z21.50 (in Canada, Improper installation, adjust- Failure to position the parts in CSA-2.22), and CAN/CGA-2.17-M91 in both USA ment, alteration, service or accordance with these diagrams...
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products General Information BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Gas Pressure - All Models Orifice Sizes - Sea Level to High Altitude Gas Valve Diagrams (All Models) Tables 2 and 3 show the appliances' inlet and See Figure 1 for Millivolt models. manifold gas pressure requirements: These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372...
  • Page 7: Cold Climate Insulation

    Innovative Hearth Products General Information BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.
  • Page 8: Vent Termination Clearances

    Innovative Hearth Products General Information BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances These instructions should be used as a Termination Heights For Vents guideline and do not supersede local codes Above Flat Or Sloped Roofs Ref.
  • Page 9: Appliance And Vent Clearances

    Innovative Hearth Products General Information BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 MINIMUM CLEARANCES TO COMBUSTIBLES Mantel Depth Appliance And Vent Clearances 14 (356) The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 5), with the following exception: When 12 (305) inches (millimeters) the unit is installed with one side flush with a wall, the wall on the...
  • Page 10: Pre-Installation Steps

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 PRE-INSTALLATION STEPS TYPICAL INSTALLATION SEQUENCE Step 6. (Page 16) Install and verify outside air kit operation. The typical sequence of installation is outlined Front face assembly Step 7. (Page 17) Checkout appliance opera- Hood below.
  • Page 11: Step 1. Framing

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Step 1. FRAMING to fit around them. All construction above the Position the fireplace within the framing. When appliance must be self supporting, DO NOT use required, the flanges may be bent 90 degrees by Frame this appliance as illustrated in Figure 9.
  • Page 12: Fireplace Specifications

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 FIREPLACE SPECIFICATIONS (See-Through) 48-1/4 (1200) Inches (millimeters) FINISHED WALL BRACKET 48 (1219) (Front and back edge of unit top) FRAMING SPACERS (Top and both sides) Stepped to accept drywall 37-3/4 (959) on all four corners 40-1/4 (1022)
  • Page 13: Step 2. Routing Gas Line

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Step 2. ROUTING GAS LINE Step 3. INSTALL THE VENT SYSTEM Schedule 40 Black Iron Pipe Route a 1/2" (13 mm) gas line to the left side General Information Inside Diameter (Inches) of the appliance as shown in Figure 11.
  • Page 14: Step 4. Field Wiring

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Step 4. FIELD WIRING Refer to Section A for millivolt appliances. The gas valve is set in place and pre-wired at the factory on both models. CAUTION: Label all wires prior to disconnec- tion when servicing controls.
  • Page 15: Step 5. Connecting Gas Line

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 STEP 5. CONNECTING GAS LINE TEST ALL CONNECTIONS FOR GAS LEAKS A. Light the appliance (refer to the lighting (FACTORY AND FIELD): instructions label in the control compart- ment or in the Installation and Operation Make gas line connections.
  • Page 16: Step 6. Outside Air Kit

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Step 6. OUTSIDE AIR KITS NOTE: Do not terminate outside air kit in attic The outside air shutter should be fully open when space under any circumstances. the fireplace is in use and completely closed when the fireplace is not being used.
  • Page 17: Step 7. Verifying Appliance Operation

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Step 7. VERIFYING APPLIANCE OPERA- MILLIVOLT Hood Igniter Rod TION Thermocouple Turn on burner and observe the individual tongues of flame on the burner. Make sure all ports are open and producing flame evenly across the burner.
  • Page 18: Step 8. Installing Logs

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Step 8. INSTALL VERMICULITE, GLOWING EMBERS AND LOGS NOTE: It is important to ensure proper log placement per the manual when installing these units. Verify pilot flame is not obstructed. See Verifying Appliance Operation on Page 17.
  • Page 19 Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 BRT40ST LOG PLACEMENT Description Number Log, Corner Log, Rear/Left Log, Front/Left Log, Rear/Right Log, Front/Center Log, Center/Top Catalog Number for the entire log set: 55M04 Log (3) Lays Over Logs 1 And 2 STEP 3 STEP 1...
  • Page 20 Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 BRT40ST LOG PLACEMENT (CONTINUED) Description Number Log, Corner Log, Rear/Left Log, Front/Left Log, Rear/Right Log, Front/Center Log, Center/Top Catalog Number for the entire log set: 55M04 Position The Round End Of Log (6) Position Small End Of Log (6) Against The Notch Of Log (4) Here.
  • Page 21: Step 9. Remove/Install Glass Door

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Step 9. REMOVING AND INSTALLING THE Step 10. BURNER ADJUSTMENTS Removing Glass Enclosure Panel (see Figure 24) GLASS DOOR Flame Appearance and sooting To access the glass door securing latches, first Proper flame appearance is a flame which is WARNING remove the hood by pulling firmly straight away...
  • Page 22: Step 11. Hood Installation

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Burner Adjustment Procedure WARNING • Air shutter adjustment should only be performed by a quali- fied professional service tech- nician. • Ensure glass enclosure panels are in place and sealed during adjustment.
  • Page 23: Step 12. Spillage Test/Safety Switch

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Step 12. Spillage Test and Safety Limit Manually-Reset Safety Limit Switch Switch Operation This appliance is equipped with a manually-reset blocked flue safety limit switch. Refer to Figure 28 for its location. If, during appliance operation, the flame goes out (independently of the burner Spillage Test on/off wall switch), it may be due to the operation of this safety limit switch.
  • Page 24: Step 13. Installer - Attaching Safety- In-Operation Warnings

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 STEP 13. ATTACHING SAFETY IN OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES...
  • Page 25: Gas Conversion Kits

    Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 GAS CONVERSION KITS Natural to Propane Gas Conversion Kit Unit Type Cat. No. WARNING Millivolt H2198 This conversion kit shall be installed by a qualified service agency in INSTALLATION INSTRUCTIONS accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 26 Innovative Hearth Products Installation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 d. Locate the latch at the top of the control Step 5. Attach manometer to the manifold compartment. To disengage the latch from side pressure test fitting and verify manifold the bottom vee-flange of the glass enclosure pressure reads 3.5"...
  • Page 27: Operation/Care Of Your Appliance

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 OPERATION AND CARE OF YOUR APPLIANCE Refer to Figure 34 for access to the gas control valve. Millivolt appliances will be fitted with the gas control valve shown in Figure 35. WARNING Millivolt Appliances - Young children should be carefully supervised when they are in the...
  • Page 28: Important Safety Information

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 IMPORTANT SAFETY INFORMATION Important Safety Informa- Información importante de L’information de sûreté tion seguridad importante 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 29: In-Operation Warnings

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES EN OPERACIÓN À LA SÉCURITÉ D’UTILISATION Your fireplace has been furnished with safety instruc- Su chimenea incluye etiquetas de instrucciones de tion labels that are to be affixed to the operation and...
  • Page 30 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 APPLIANCE INSTALLATION, SERVICE, APPLIANCE OPERATION NOTICES WARRANTY INFORMATION AND MAINTENANCE NOTICES Do not operate appliance with the glass Your gas appliance is covered by a limited front removed, cracked, or broken. 20-year warranty.
  • Page 31 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 These appliances comply with National Safety Deration - At higher elevations, the amount Gas Pressure - All Models Standards and are tested and listed by PFS of BTU fuel value delivered must be reduced Tables 9 and 10 show the appliances' inlet and by either using gas that has been derated by (Report No.
  • Page 32 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Outside Combustion Air Controls Variable Flame Height Adjustment Inlet Pressure Port Many appliances are equipped, when installed, Manifold Pressure Port with an outside (make-up air) vent system that is designed to provide the appliance with outside make-up air for combustion when in operation.
  • Page 33 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Manual-Reset Safety Limit Switch B - To access the blocked flue safety switch: WARNING This appliance is equipped with a manual-reset NOTE: This procedure should only be performed Do not operate the shutoff lever blocked flue safety limit switch.
  • Page 34: Maintenance

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 MAINTENANCE IMPORTANT: Do not use abrasive clean- Replacing Logs ers on glass. Never clean the glass when (See Maintenance Schedule, Page 44) If the logs become damaged by accident or it is hot.
  • Page 35: Front Glass Enclosure Panel, Removal And Installation

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Front Glass Enclosure Panel, Removal Locate the latch at the top of the control com- WARNING partment and disengage them from the door and Installation frame bottom vee-flange, pulling down on its Any safety screen or guard handle to open it.
  • Page 36: Install Vermiculite, Embers And Logs

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 INSTALL VERMICULITE, GLOWING EMBERS AND LOGS NOTE: It is important to ensure proper log placement per the manual when installing these units. Verify pilot flame is not obstructed. See Verifying Appliance Operation on Page 17.
  • Page 37 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 LOG PLACEMENT Description Number Log, Corner Log, Rear/Left Log, Front/Left Log, Rear/Right Log, Front/Center Log, Center/Top Catalog Number for the entire log set: 55M04 Log (3) Lays Over Logs 1 And 2 STEP 3 STEP 1...
  • Page 38 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 LOG PLACEMENT (CONTINUED) Description Number Log, Corner Log, Rear/Left Log, Front/Left Log, Rear/Right Log, Front/Center Log, Center/Top Catalog Number for the entire log set: 55M04 Position The Round End Of Log (6) Against The Notch Of Log (4) Here.
  • Page 39: Install Vermiculite, Embers And Logspage 36 Burner Flame Appearance/Sooting

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 BURNER ADJUSTMENTS Air Shutter Adjustment Guidelines The following chart is provided to aid you in achieving the correct air shutter adjustment (QUALIFIED TECHNICIANS ONLY) • If there is smoke or soot present, first check for your installation.
  • Page 40: Burner Flame Adjustments

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 Burner Flame Adjustments Air Shutter MILLIVOLT Hood Igniter Rod Adjusting WARNING Thermocouple Orifice • Air shutter adjustment should only be performed by a quali- fied professional service tech- 3/8" Min nician.
  • Page 41: Wiring Diagrams

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 WIRING DIAGRAM A wiring diagram is provided here for reference purposes only. This information is also provided THERMOPILE on schematics attached directly to the appliance on a pullout panel located within the control compartment.
  • Page 42: Accessory Components

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 ACCESSORY COMPONENTS Bag of Glowing Embers Bag of Volcanic Stone Bag of Vermiculite Replacement ember materials, volcanic stone or vermiculite are available for use with these appli- Firebox Liner Kit ances.
  • Page 43 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 ACCESSORY COMPONENTS CONTINUED Wall Control Cost Effective Solution • 4-button timer with 30/60/120/OFF minutes • Simple On/Off operation • Wall surface mounted • Connects to wall switch wire Manual or up to 3 hr Countdown Timer modes Kit includes: •...
  • Page 44: Maintenance Schedule

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 MAINTENANCE SCHEDULE Annually (Before the onset of the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping and Controls for leaks.
  • Page 45: Lighting Instructions - Millivolt

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 46 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 47: Troubleshooting Guide - Millivolt

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 TROUBLESHOOTING NOTE: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 48: Replacement Parts List

    Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 REPLACEMENT PARTS LIST Natural and Propane Gas Controls — SIT Millivolt Qty. Natural Propane Description Part No. Description Part No. Qty. Part No. Qty. Hood, Black - 40" J7536 Gas Valve - SIT H6209 88J53...
  • Page 49 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 REPLACEMENT PARTS NOTE: See the tables on Page 48 for replacement parts applicables. Cat. No. Model F0838 BRT40STTMN Inside Location NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 50 Innovative Hearth Products Operation BRT40ST See-Through B-Vent Gas Fireplaces 900301-00 05/2016 NOTES NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 51: Warranty

    ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials ® and workmanship at the time of manufacture. The Product body and fi rebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 52 Innovative Hearth Products Installation and Operation Instructions BRT40ST See-Through B-Vent Gas Fireplace 900301-00, 05/2016 SuperiorFireplaces.US.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discon- tinue colors, styles and products.

Table of Contents