Superior BRT4036TEN Installation And Operation Instructions Manual

Custom series decorative b-vent fireplace electronic ignition system

Advertisement

P/N 126737-01 Rev. B 04/2014
P126737-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING AVERTISSEMENT AVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Installation and Operation Instructions
Superior™ Custom Series Decorative B-Vent Fireplace
Electronic Ignition System
PFS
Models
®
BRT4036TEN
C
US
BRT4336TEN
BRT4536TEN
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE
AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT DE
TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
BRT4042TEN
BRT4036TEP
BRT4342TEN
BRT4336TEP
BRT4542TEN
BRT4536TEP
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA TOCAR
EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
BRT4042TEP
BRT4342TEP
BRT4542TEP

Advertisement

Table of Contents
loading

Summary of Contents for Superior BRT4036TEN

  • Page 1 Installation and Operation Instructions Superior™ Custom Series Decorative B-Vent Fireplace Electronic Ignition System P/N 126737-01 Rev. B 04/2014 Models ® BRT4036TEN BRT4042TEN BRT4036TEP BRT4042TEP BRT4336TEN BRT4342TEN BRT4336TEP BRT4342TEP BRT4536TEN BRT4542TEN BRT4536TEP BRT4542TEP P126737-01 INSTALLER: Leave this manual with the appliance.
  • Page 2: Table Of Contents

    WARNING: Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in- stallation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier. NOT FOR USE WITH SOLID FUEL CHECK LOCAL CODES PRIOR TO INSTALLATION SAVE THIS BOOK...
  • Page 3: Safety

    SAFETY 1. This appliance is only for use with the type WARNING: This product con- of gas indicated on the rating plate. This tains and/or generates chemicals appliance is not convertible for use with other gases unless a certified kit is used. known to the State of California 2.
  • Page 4: Unpacking

    YOU MAY CAUSE A FIRE HAZARD! fuel burning appliance. The INNOVATIVE HEARTH PRODUCTS warranty will be voided by and INNOVATIVE Models BRT4036TEN, 4336TEN, 4536TEN, HEARTH PRODUCTS disclaims any respon- 4042TEN, 4342TEN, 4542TEN are factory sibility for the following actions: equipped for use with natural gas and must...
  • Page 5: Selecting Location

    INTRODUCTION Continued gas approved for use in this gas appliance. CAUTION: Do not connect The installation must conform with local appliance before pressure test- codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI ing gas piping.
  • Page 6: Product Specifications

    PRODUCT SPECIFICATIONS GAS RATING - NATURAL BRT 4036TEN, BRT 4042TEN, 4342TEN, 4336TEN, 4536TEN 4542TEN Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5" WC (.87 kPa) 3.5" WC (.87 kPa) Minimum Supply Pressure: 4.5" WC (1.12 kPa) 4.5" WC (1.12 kPa) Maximum Supply Pressure: 10.5"...
  • Page 7: Pre-Installation Preparation

    PRE-INSTALLATION PREPARATION CLEARANCES MANTEL CLEARANCES AND WALL DETAILS Minimum clearances to combustibles are: Back and Sides of Outer Surround 0" min. A combustible mantle shelf maybe installed a maximum 12" (22.9 cm) from wall. Figures 5 Drywall to Sides of Front Face and 6 show the minimum allowable distances (Nailing Flanges) 0"...
  • Page 8 PRE-INSTALLATION PREPARATION Continued FRAMING These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" 1. Frame appliance enclosure as illustrated in Clearance is Permitted Figures 7 and 8. Note: If a wall covering is used to line enclo- sure, then all measurements must be from surface of covering.
  • Page 9: Requirements For The Commonwealth Of Massachusetts

    REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS INSPECTION For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or The state or local gas inspector of the side structure used in whole or in part for residential wall horizontally vented gas fueled equipment purposes, including those owned or operated by shall not approve the installation unless, upon...
  • Page 10: Venting Installation

    VENTING INSTALLATION A B-type venting system must be connected at 60° or greater. The total vertical height in to appliance for venting to the outside of this example represents the minimum height building. of 8 feet and therefore the allowable lateral is 6 feet when the 75% rule applies.
  • Page 11 VENTING INSTALLATION Continued Listed Vent Cap Listed Listed Vent Cap Vent Cap Maintain Maintain Listed Listed Clearance Clearance Maintain Listed Maintain Support Each Clearance Listed Lateral At Clearance Least Every 45° 60° 6 Feet 12' Min. 45° Position Position Firestop Firestop Position 12' Min.
  • Page 12: Installation

    VENTING INSTALLATION Continued CHECKING FOR PROPER VENTING NOTICE: This appliance is After completing and checking electrical, equipped with a vent safety gas and vent connections, follow the lighting shutoff switch which will shut instructions and allow the main burner to run down the appliance in the case of for approximately 5 minutes.
  • Page 13 INSTALLATION Continued INNOVATIVE HEARTH PRODUCTS recom- 3. Activate remote handset battery by re- mends that a black iron gas line be routed moving insulating tab on back of handset from the gas source, through a sediment trap (see Figure 15). Battery is included pre- (shown in Figure 18) and into appliance.
  • Page 14 INSTALLATION Continued Complete your gas installation by connect- CAUTION: Compounds used ing incoming gas line with flexible gas line. on threaded joints of gas piping Secure tightly with wrench but DO NOT OVERTIGHTEN. shall be resistant to the action of Liquefied Petroleum (LP or EMBER AND PAN MATERIAL propane) and should be applied PLACEMENT...
  • Page 15 Figure 25 - Installing Logs 5 and 6 Log 2 Notch Log 1 Figure 26 - Logs Installed for BRT4036TEN/TEP, BRT4336TEN/TEP and Figure 23 - Installing Logs 1 and 2 BRT4536TEN/TEP Models www.SuperiorFireplaces.US.com 126737-01B...
  • Page 16 INSTALLATION Continued LOG PLACEMENT FOR MODEL 5. Place upper end of log 5 into notch on top inner right of log 1 (see Figure 29). Rest BRT 4042TEN, 4342TEN, 4542TEN, lower end of log 5 on middle grate finger 4042TEP, 4342TEP, 4542TEP as shown in Figure 30.
  • Page 17 INSTALLATION Continued COMBUSTION AIR KIT MODEL AK4 INSTALLING OPTIONAL GLASS (OPTIONAL) DOOR ACCESSORY The outside air kit may be installed on the left CAUTION: Use only glass side of fireplace only. The vent can be installed doors certified for use with this through any outside wall a minimum of three feet below fireplace termination cap.
  • Page 18 INSTALLATION Continued 6. Repeat process for opposite door as- Spring Hold-Down Clip sembly. Screw 7. To adjust doors, slide them partially open. Side Using a screwdriver, loosen hold-down Front screws in the spring clip (see Figure 34) Face and pivot plate. 8.
  • Page 19: Operation

    OPERATION FOR YOUR SAFETY 1. STOP! Read the safety information, col- umn 1. READ BEFORE LIGHTING 2. Turn wall switch (if installed) to the OFF WARNING: If you do not fol- position. low these instructions exactly, 3. Turn off all electric power to appliance. a fire or explosion may result 4.
  • Page 20: Inspecting Burners

    OPERATION Continued TO TURN OFF GAS 1. Turn equipment shutoff valve to ON posi- tion. You can now turn burner on and off TO APPLIANCE with the hand-held remote control unit. 1. Turn off wall switch. IMPORTANT: Be sure to press ON/OFF 2.
  • Page 21: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING: Failure to keep WARNING: Installation and the primary air opening(s) of repair should be done by a quali- the burner(s) clean may result in fied service person. The appli- sooting and property damage. ance should be inspected before each use and at least annually PILOT AND BURNER by a qualified service person.
  • Page 22: Wiring Diagram

    WIRING DIAGRAM Pilot Burner INCOMING WALL SWITCH MAIN GAS (NOT SUPPLIED) SUPPLY Pilot Gas Line BLACK INCOMING 120V AC WHITE (FUSE BOX GREEN VENT SAFETY OR BREAKER) SHUTOFF SWITCH MANUAL DAMPER SWITCH ELECTRICAL RATING: 120v, 60Hz, 0.7A 24V AC STEP DOWN TRANSFORMER 120V AC OPTIONAL...
  • Page 23: Troubleshooting

    TROUBLESHOOTING Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 24 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
  • Page 25: Accessories

    ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. Purchase these accessories from your local dealer. If they can not supply these accessories call INNOVATIVE HEARTH PRODUCTS at 1-800-655-2008 for information. You can also write to the address listed on the back page of this manual. BRICK LINER KIT AIR KIT - AK4 (For M36(B,H), M36P(B,H), M42(B,H) and...
  • Page 26: Parts

    PARTS MODELS BRT 4036TEN/ 4336TEN/ 4536TEN/ 4042TEN/ 4342TEN/ 4542TEN/ 4036TEP/ 4336TEP/ 4536TEP/ 4042TE/ 4342TEP/ 4542TEP 35 34 www.SuperiorFireplaces.US.com 126737-01B...
  • Page 27 PARTS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual. 36' MODELS 42" MODELS DESCRIPTION 14153 14153 Micro Switch 109098-01 109098-01 Wire Harness 108863-01 108863-01 24"...
  • Page 28 PARTS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual. KEY NO. 36" Models 42" Models DESCRIPTION BRT4036TEN BRT4042TEN BRT4036TEP BRT4042TEP BRT4336TEN BRT4342TEN BRT4336TEP...
  • Page 29 PARTS LOGSETS FOR MODELS BRT4036TEN, BRT4336TEN, BRT4536TEN, BRT4036TEP, BRT4336TEP AND BRT4536TEP NO. PART NO. DESCRIPTION QTY. 107999-01 Log Set 108724-01 Right Front 9" Split Log 901098-01 Rear Log 108720-01 Top Right Log - 11 " 108721-01 Top Right Log - 16"...
  • Page 30 PARTS LOGSETS FOR MODELS BRT4042TEN, BRT4342TEN, BRT4542TEN, BRT4042TEP, BRT4342TEP AND BRT4542TEP NO. PART NO. DESCRIPTION QTY. 107999-02 Log Set 901098-02 Rear Log 108723-01 Left Front Log - 11" 108839-01 Right Front Log - 15 " Round 108722-01 Top Left Log - 13 "...
  • Page 31: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 32 KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents