CONTROL I/O

This connector allows for remote control by suitably-
equipped units, and provides tally information to
such units.
The total current of pin 6 (+5 V) and pin 8 must be
less than 100 mA.
Pin
1
PLAY command (drive 2)
2
STOP command (drive 2)
3
CALL command (drive 2)
4
FADER command (drive 2)
5
Not connected
6
+5 V
7
Not connected
8
+5 V
9
Not connected
10
PLAY command (drive 1)
11
STOP command (drive 1)
12
CALL command (drive 1)
13
FADER command (drive 1)
14
PLAY tally (drive 2)
15
READY tally (drive 2)
16
EOM tally (drive 2)
17
GND
18
Not connected
19
Not connected
20
Not connected
21
Not connected
22
PLAY tally (drive 1)
23
READY tally (drive 1)
24
EOM tally (drive 1)
25
GND
9 – External control—CONTROL I/O
Input signals are active when grounded for at least
30 ms.
Output signals are connected to an open collector
with maximum voltage 15 V, and maximum current
50 mA.
Signal name
TASCAM CD-RW402 Owner's Manual
IN/OUT
IN
IN
IN
IN
IN
IN
IN
IN
OUT
OUT
OUT
OUT
OUT
OUT