Table 5. Checking Specifications - Aqua Lung Legend First Stage Service Manual

Legend first stage aqualung
Hide thumbs Also See for Legend First Stage:
Table of Contents

Advertisement

F I R S T
T O
D I V E
REFERENCE N°
129122
129124
129125
129120
129194, 129196
TEST
Leak Test
160 bar < Working pressure < 200 bar
Medium Pressure
160 bar < Working pressure < 200 bar
MP Variation
160 bar < Working pressure < 200 bar
Table 4. Torque values
DESCRIPTION
Dry chamber (6)
DIN Seat (30)
Chromed plugs (14)

Table 5. Checking specifications

INSTRUCTIONS
Seat (29)
Plug (20)
No leak
MP to 9.5 bar ± 0.5 bar: Legend and Legend LX
MP to 8.5 bar ± 0.5 bar: Legend Supreme and Legend LX
Supreme
After purging the regulator several times, the MP should not
increase by more than 0.3 bar in 5-15 seconds.
FORCE
2.5 m.kg.
2.5 m.kg.
2.5 m.kg.
0.5 m.kg.
0.4 m.kg.
SPECIFICATIONS
15