Table 5. Checking Specifications - Aqua Lung SECOND STAGE Service Manual

Second stage
Table of Contents

Advertisement

F I R S T
T O
D I V E
N° REFERENCE
AP2031
TEST
Leak Test
160 bar < Working pressure < 200 bar
Medium Pressure
160 bar < Working pressure < 200 bar
Opening effort
160 bar < Working pressure < 200 bar
Effort / Flow
MP at 9.5 bar ± 0.5 bar: Legend LX
MP at 8.5 bar ± 0.5 bar: Legend LX
Supreme
Table 4. Torque values
DESCRIPTION

Table 5. Checking specifications

INSTRUCTIONS
Nut (5)
No leak
MP at 9.5 bar ± 0.5 bar: Legend and Legend LX
MP at 8.5 bar ± 0.5 bar: Legend Supreme and Legend LX
Supreme
Legend LX: between 2.5 mbar et 3.5 mbar
Legend LX Supreme: between 3.3 and 4.3 mbar
15 mbar maxi at 400 L/min
COUPLE
0.5 m.kg.
SPECIFICATIONS
15