4
4.
The acronyms used:
LP: Low Pressure
MP: Medium Pressure
HP: High Pressure
5.
Numbers in brackets indicate the part number of the
component shown on the exploded view attached.

DISASSEMBLY PROCEDURE

Note: Before commencing disassembly, consult
the exploded view to check the reference
numbers of all parts requiring replacement.
These parts should all be replaced by new parts
and should not be re-used on the pretext that
the regulator has seen little use since its
manufacture or since its last service.
Attention: Use only the special tool when
removing O-rings in order to avoid damaging the
seal recess. The slightest scratch on a sealing
surface could cause a leak. If a surface should be
damaged then this part should be replaced with a
new one. Do not use any pointed instrument or
metal tool to remove O-rings.
Legend First Stage Service Manual
1.
Unscrew the hoses from the first stage using the
appropriate spanner. Screw the HP and MP plugs into
the open ports but leave one HP and one MP port free.
2.
Use an 8mm Allen key to unscrew the plug (14) .
Remove the ribbed washer (11).
3.
Manually remove the diaphragm (13). Turn the body
over to allow the piston (12) to fall into your hand.
4.
Manually remove the
spacer (10) by sliding
it along the dry
chamber (6).
5.
Use an 8mm Allen key to unscrew the adjusting screw
(9). Remove the washer (8) and then the spring (7).
Note: The washer may stick in the inside of the
adjusting screw. If this occurs, lightly tap the screw
onto your palm to release it and allow the washer
to drop out.