Actual capacity [L]
Materials
- inner cylinder
- outer cylinder
- inlet/outlet
- coils
- insulation
Maximum operating conditions
- potable water temperature
- heating water temperature
- operating pressure
Cold water supply
- minimum dynamic pressure
- maximum pressure
- minimum flow rate
Connections
- cold water inlet
- hot water outlet
- coil flow and return
Coil specification
- surface area [m²]
- rating [kW]
Immersion heater
Thermostatic control
- direct input
- indirect input
Safety components
- pressure reducing valve and strainer
- expansion relief valve
- temperature and pressure relief valve
- factory pressure test
Other features
Approvals
Guarantee
- inner cylinder
- immersion heaters
- other components
Heat Pump Cylinder Range
125
120
Duplex stainless steel LDX2101
HIPS
Stainless steel
Stainless steel
60mm PU foam (GWP=1, ODP=0)
70°C
95°C
3 bar
1.5 bar
12 bar
15 l/min
22mm stainless steel
22mm stainless steel
28mm stainless steel
1 ¾ F BSP 3kW @ 240 V
integral immersion heater thermostat and cut out
integral twin thermostat (10 to 70°C) and cut out
(~85°C)
3 bar
6 bar
½" 7 bar/90°C
12 bar
Over 60% in volume from recycled materials
Surface mounted sensor devices for compatibility
and ease of maintenance
KIWA approval number:- 1012717
KIWA
25 yrs
2 yrs - excluding the effects of lime scale or other
water borne contaminants
2 yrs - excluding expansion vessel membrane
pressure
Table 4: Heat Pump Product features
Technical Data
150
210
145
210
2.2
2.8
45
51
250
300
250
300
3.0
3.2
3.0
47
43
TBC