9 Technical data

Figure 8: Heat Pump Cylinder and Cross-section (for reference only)
Reference
Weight (full) [kg]
Reheat time [mins]*
Average draw off temperature [°C]*
Hot water draw off capacity (l)* /
draw off flow rate (l/s)
HX performance [kW]*
Heat loss [kWh]
Height [mm]
Outer Diameter [mm]
HW Outlet [mm]
T&P Valve [mm]
Secondary Return [mm]
CW Inlet [mm]
Bottom Immersion [mm]
HP Return [mm]
HP Flow [mm]
Bottom Thermostat [mm]
Note: All measurements are taken from the base of the cylinder to the mid point on the item.
* Determined in accordance with EN12897 at 80°C flow temperature and 0.42l/s flow rate.
Heat Pump Cylinder Range
Table 3: Heat Pump Cylinder Dimensions
Technical Data
125
150
210
152
182
251
7
7
12
61
60
62
97
120
180
0.25
0.25
0.25
45
51
47
-
-
960
1130
1505
580
580
580
730
900
1275
730
900
1275
-
-
967
190
190
190
208
208
208
190
190
190
710
845
895
460
545
732
250
300
302
350
17
20
63
62
238
267
0.25
0.50
47
43
-
-
-
1780
2080
580
580
1550
1850
1550
1850
1105
1255
190
190
208
208
190
190
895
930
870
1020