Clearances; Mantel & Trim; Alcove - Jøtul GF 600 DV Firelight Installation And Operation Instructions Manual

Direct vent gas heater
Table of Contents

Advertisement

Stove and Vent Clearance
Requirements
Minimum Clearances from the Stove to
Combustibles: See Figs. 2-4.
Rear:
3" (75 mm)
Ceiling:
33" (840 mm)
Corner:
3" (75 mm)
Right Side: 4" (100 mm)
Left Side: 10" (254 mm)
plate
Minimum Clearances from the Vent Pipe
to Combustibles:
Horizontal Run:
Off the top of the pipe -
Off the sides and bottom -
Vertical Run:
All sides
24" or greater depth of ceiling
10" or less in depth
33"
29"
84 cm
74 cm
Figure 2. Mantel and Trim Clearances.
- for access to Lighting Instruction
2"(50mm)
1"(25mm)
1"(25mm)
REAR CLEARANCE = 3" (75 mm)
3" (7.5 cm)
10"
(25.5 cm)
Left Side*
* Allow 10" on left side of the appliance for
complete access to the lighting instructions
and control valve.
Figure 3. Parallel Installation Clearances
3 "
(7.5 cm)
Figure 4. Corner Installation Clearance.

ALCOVE:

MAXIMUM ALCOVE DEPTH: 24" (61 cm)
MINIMUM ALCOVE WIDTH: 44" (112 cm)
MINIMUM CEILING HEIGHT: 64" (163 mm)
4"
(10 cm)
Right Side
3"
7.5 cm
7