Gas Conversion Procedure
All numbers in ( ) refer to the exploded view on
page 25 of this manual.
1. Turn off gas supply to the stove.
2. Remove the top griddle (7).
3. Locate the two set screws near the top of each
side casting (3, 8). Using a 3mm allen wrench
thread the set screws out. Lift off the top panel
of the stove (6).
4. Open the front doors of the stove using the stove
tool.
5. Release the glass clips (17) atop the firebox (22)
and slowly lift glass assembly (16) up and out.
6. Remove the four logs (36) using care not to
scratch or damage the logs.
7. Using a 1/4" nut driver remove the two hex head
screws that secure the air divider (21) to the
front log support (18) and lift out of the firebox
(22). See Figure 12.
Front Log
Burner
Support
Tube
Figure 12. Remove the Air Divider and Log Support.
8. Shift the burner tube (19) to the right and lift
out. Note: There are no screws securing the
burner tube to the floor of the firebox. Simply
lift the rear of the tube slightly and then lift the
entire tube.
9. Change the main burner orifice. Using a ½" open
ended wrench or deep-well socket remove the
burner orifice from the brass orifice holder.
Replace with the appropriate orifice supplied in
the kit.
3.3 mm for NG
#48 for LP
10. Adjust the air shutter on the burner tube (19) to
Figure 13. Air shutter adjustment.
11. Change the Pilot Orifice. From within the
12. Tighten orifice into the base of the pilot assem-
Air
Divider
Figure 14. Remove pilot head and pilot orifice.
allow for the proper mixing of air and gas. See
Fig. 13.
1/2" open for natural
7/8" open for propane
AIR SHUTTER
BURNER TUBE
ATTENTION: Air shutter should never be
LESS than 1/8" open.
firebox, pull the pilot hood off the pilot assembly.
See Fig. 14. Using the 4 mm allen wrench in-
cluded with the conversion kit, remove the
original pilot orifice (counterclockwise). Replace
with the appropriate orifice:
#51 for natural gas
#30 for propane
bly. Be sure the orifice is tightly secured to
prevent bypass leakage. Replace pilot hood onto
the pilot assembly.