Section 8: Programming Descriptions
The following is a brief description of the features and options available in the control panel.
Section [000] Keypad Function Key Programming
The five function keys can be reprogrammed with following functions. See Keypad Function Key Programming on page 16 for defaults
Option
Description
[00]
Null Key: Program non functioning keys with this option
[03]
Stay Arm: See Stay Arm on page 11
[04]
Away Arm: See Away Arm on page 11
[05]
No Entry Arm: See [ ][9] on page 13
[06]
Chime On/Off: See [ ][4] on page 12
[08]
Bypass: See [ ][1] on page 11
[13]
Command Output #1: See [ ][7][1] on page 13
Section [001]-[002] Zone Definitions
Option
Description
[00]
Null Zone: Zone not used
[01]
Delay 1: When armed, provides entry delay when violated (follows Entry Delay 1)
[02]
Delay 2: When armed, provides entry delay when violated (follows Entry Delay 2)
[03]
Instant: When armed, instant alarm when violated
[04]
Interior: When armed, instant alarm if the zone is violated first, will follow entry delay if entry delay is active
[05]
Interior Stay/Away: Similar to 'Interior' except panel will auto-bypass the zone if armed in the Stay mode
[06]
Delay Stay/Away: Similar to 'Delay 1' except panel will auto-bypass the zone if armed in the Stay mode
[07]-[08]
Future Use
[09]
24-Hour Supervisory (Hardwired): Instant Alarm, silent at default.
[10]
24-Hour Supervisory Buzzer: Instant alarm, panel will activate keypad buzzer instead of bell output
[11]
24-Hour Burglary: Instant alarm when violated, audible alarm at default.
[12]
Future Use
[13]
24-Hour Gas: Instant alarm when violated, audible alarm at default.
[14]
24-Hour Heat: Instant alarm when violated, audible alarm at default (also known as high-temp).
[15]
24-Hour Medical: Instant alarm when violated, audible alarm at default.
[16]
24-Hour Panic: Instant alarm when violated, audible alarm at default.
[17]
24-Hour Emergency: Instant alarm when violated, audible alarm at default.
[18]
Future Use
[19]
24-Hour Water: Instant alarm when violated, audible alarm at default (also known as flood).
[20]
24-Hour Freeze: Instant alarm when violated, audible alarm at default (also known as low-temp).
[21]
Future Use
[22]
Momentary Keyswitch Arm: Arms or disarms the system when violated
[23]
Maintained Keyswitch Arm: Arms system when violated, disarms system when restored
[24]
For Future Use
[25]
Interior/Delay: Function as an Interior zone when armed in Away mode, and as a Delay zone when armed in the Stay mode
[26]
24-Hour Non-Alarm: Zone will NOT create an alarm. Can be used with chime to identify a specific event.
[27]-[31]
Future Use:
[32]
Instant Stay/Away: Similar to 'Instant' except panel will auto-bypass the zone if armed in the Stay mode
[33]-[35]
Future Use
[36]
24-Hour Non-Latching Tamper: Instant tamper condition when violated. Active in armed and disarmed state.
WWW.DIYALARMFORUM.COM
Section 8: Programming Descriptions
Option
Description
[14]
Command Output #2: See [ ][7][1] on page 13
[16]
Quick Exit: See [ ][0] on page 13
[17]
Reactivate Stay/Away Zones: See [ ][1] on page 11
*[27]
Disarm: See Disarm on page 11
*[29]
[A]ux Alarm: Same as [A] key
*[30]
[P]anic: Same as [P] key.
*Applies to Key Fobs only (See Section [804] Subsection [61]-[76]