[600] 2-way Audio Control Options (Applies to SCW9047 only)
Opt
Def.
ON
1
Tampers Enabled
2
Openings & Closings Enabled
3
[A] Key Alarm Enabled
4
[P] Key Alarm Enabled
5
Duress Alarm Enabled (Listen)
6
Opening after Alarm Enabled
*7
Bell Active during 2-way Audio Verification.
8
Future Use
* This option must be ON for UL Listed Installations
INTERNATIONAL PROGRAMMING
[700] Automatic Clock Adjust
Default = 60
|________|_________|
[701] First International Options
Opt
Def.
ON
1
50 Hz AC
EU
2
Time Base - Internal Crystal
3
AC/DC Arming Inhibit Enabled
4
All System Tampers Require Installer Reset
5
6-digit User Access Codes
6
Busy Tone Detection Enabled
7-8
Future Use
[702] Second International Options
Opt
Def.
ON
1
Pulse Dialing Make/Break Ratio is 33/67
2
Force Dialing Enabled
3
Future Use
4
1600Hz Handshake
5
ID Tone Enabled
6
2100 Hz ID Tone
7-8
Future Use
[703] Delay Between Dialing Attempts
Default = 003
|________|________|________|
Valid Entries 01-99 Seconds
Valid Entries are 000-255 Seconds (Entry + 5 seconds)
WWW.DIYALARMFORUM.COM
OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Bell Silent during 2-way Audio Verification.
OFF
60 Hz AC
NA
Time Base - AC Line
AC/DC Arming Inhibit Disabled
All System Tampers Follow Restoral
4-digit User Access Codes
Busy Tone Detection Disabled
OFF
Pulse Dialing Make/Break Ratio is 40/60
Force Dialing Disabled
Standard Handshake
ID Tone Disabled
1300 Hz ID Tone
7.2 Programming Worksheets