DSC PowerSeries Installation Manual page 21

Self contained wireless alarm system v1.0
Hide thumbs Also See for PowerSeries:
Table of Contents

Advertisement

[005] System Times
Valid entries for Entry Delay are between 030-255, valid entries for SIA CP-01 Exit Delay is between 045-255.
030
I___I___I___I
I_0_I_3_I_0_I
045
120
I_0_I_6_I_0_I
004
I___I___I___I
For SIA CP-01 compliant installations, the Exit Delay must be within the range of 045-255 seconds
(Default 60 seconds). If the Exit Delay is silent (Section 14, Option 6 or Stay Function Key Arming) the exit delay
must be twice the programmed value but must not exceed 255 seconds (i.e., 090-255 seconds).
For UL Installations, the Entry Delay plus the Communications Delay must not exceed 60 seconds.
[006] Installer's Code
Default
5555
I_______I_______I_______I_______I
Programmable Output Options
00
Null PGM (Not Used)
Residential Burglary and Fire Bell Output
01
02-04 Future Use
System Armed Status
05
06
Ready To Arm
07
Keypad Buzzer Follower
Courtesy Pulse
08
09
System Trouble Output (with Trouble Options)
[009] I/O Programming
Program Zone Definition Attributes in Sections [133-134], Program PGM Option Attributes in sections [501] - [502]
Default
00
I/O Type (Zone 33, PGM 1)
I_______I_______I
00
I/O Type (Zone 34, PGM 2)
I_______I_______I
[012] Keypad Lockout Options
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
Number of Invalid Codes Before Lockout (Valid entries are 000-255)
I_______I_______I______I
000
Lockout Duration (in minutes)
I_______I_______I______I
[013] First System Options
Opt
Def. ON
1
Hardwired Zone 33 Input Enabled
2
Hardwired Zone 34 Input Enabled
3-5
Future Use
6
Audible Exit Fault Enabled
7
Event Buffer follows Swinger Shutdown
8
Temporal Three Fire Signal Enabled
Entry Delay 1
Entry Delay 2
Exit Delay
Bell Cut-off
[007] Master Code
Default
1234
I_______I_______I_______I_______I
WWW.DIYALARMFORUM.COM
10
System Event Output (with Event Options)
System Tamper (all sources: zones, keypad)
11
12
TLM and Alarm
13-16 Future Use
17
Away Armed Status
18
Stay Armed Status
Command Output #1 ([ ][7][1])
19
20
Command Output #2 ([ ][7][2])
Enter Zone Definition or PGM Definition
Enter Zone Definition or PGM Definition
(Valid entries are 000-255)
OFF
PGM1 Output Enabled
PGM2 Output Enabled
Audible Exit Fault Disabled
Event Buffer Logs Past Shutdown
Standard Pulsed Fire Signal