Vanner IT12-1400 Owner's Manual

Vanner IT12-1400 Owner's Manual

It series industrial true sine wave ac power inverter
Hide thumbs Also See for IT12-1400:
Table of Contents

Advertisement

IT SERIES
I
ndustrial
AC Power Inverter
IT12-1400
IT12-2000
IT12-1600
IT12-2200S
IT12-1800
IT12-2400
Owners Manual D98494
IT SERIES Industrial True Sine Wave Inverter
T
rue Sine Wave
Models
IT12-2600
IT12-2800
IT12-3000
Owners Manual
Owners Manual
IT12-3200
IT12-3600PL
IT24-3500
June 18, 2001
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IT12-1400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vanner IT12-1400

  • Page 1 Owners Manual IT SERIES ndustrial rue Sine Wave AC Power Inverter Models IT12-1400 IT12-2000 IT12-2600 IT12-3200 IT12-1600 IT12-2200S IT12-2800 IT12-3600PL IT12-1800 IT12-2400 IT12-3000 IT24-3500 Owners Manual D98494 June 18, 2001 IT SERIES Industrial True Sine Wave Inverter Owners Manual...
  • Page 2 IT SERIES Owner's Manual Typical Installation Alternator OEM Wire OEM Wire OEM Wire Charging Fuse 250 Amp Minimun Battery Common OEM Ground at Starter or Engine Block Charging Fuse 250 Amp Minimum Inverter Fuse See Figure 10 for Fuse and Wire Size Inverter Inverter Batteries...
  • Page 3: Table Of Contents

    Table of Contents TABLE OF CONTENTS INTRODUCTION ..........................5 SPECIFICATIONS AND FEATURES....................6 ..........................6 PECIFICATIONS ..........................8 TANDARD EATURES ........................9 ARTS AND CCESSORIES SAFETY INSTRUCTIONS ......................10 README............................10 ........................10 ENERAL RECAUTIONS ......................11 XPLOSIVE RECAUTIONS ........................11 ATTERY RECAUTIONS COMPONENT IDENTIFICATION AND DESCRIPTION OF OPERATION ........12 (4) A ) ............13 HROTTLE...
  • Page 4 Table of Contents PREVENTIVE MAINTENANCE AND TROUBLE SHOOTING PROCEDURES....... 24 ........................ 24 REVENTIVE AINTENANCE ..................... 24 ROUBLE HOOTING ROCEDURES APPENDIX............................. 26 ............................26 ARRANTY GFCI T ......................... 27 ECORD List of Figures and Tables 2400 ..........6 IGURE PECIFICATIONS FOR MODELS RATED UP THROUGH WATTS 2600 ..........
  • Page 5: Introduction

    Introduction 1 INTRODUCTION Thank you for purchasing a Vanner IT SERIES Inverter. We are confident that you will be satisfied with its performance and its many features. With proper installation and care, you can look forward to years of service from this high performance product.
  • Page 6: Specifications And Features

    Specifications and Features 2 Specifications and Features Specifications Figure 1 Specifications for models rated up through 2400 watts. Model Number SPECIFICATIONS IT12-1400 IT12-1600 IT12-1800 IT12-2000 IT12-2400 IT12-2200S AC Power Output Rated Output Watts * 1400W 1600W 1800W 2000W 2200W 2400W 11.7A...
  • Page 7: Watts And Higher

    Specifications and Features Figure 2 Specifications for models rated 2600 watts and higher Model Number SPECIFICATIONS IT12-2600 IT12-2800 IT12-3000 IT12-3200 IT24-3500 IT12-3600PL AC Power Output 3600W for Rated Output Watts * 2600W 2800W 3000W 3200W 30 minutes 3500W minimum** 21.7A 23.3A 25.0A 26.7A...
  • Page 8: Standard Features

    Specifications and Features Standard Features True sine wave 120 volt AC output. Total harmonic distortion less than 4% for all loads up to the Surge Output Rating. Resilient electronic protection designed to handle output short circuits and output overloads. Built-in Volt Guard Battery Voltage Monitor, providing ground control for an automatic throttle to insure maximum alternator output when needed.
  • Page 9: Parts And Accessories

    Description 03644 Bussmann Fuse ANL-250 250 amp DC fuse for charging cable 04521 Bussmann Fuse ANN-300 300 amp DC input fuse for IT12-1400 thru IT12-2000 04523 Bussmann Fuse ANN-400 400 amp DC input fuse for IT12-2200S 03646 Bussmann Fuse ANL-500...
  • Page 10: Safety Instructions

    4. To avoid the risk of fire, electrical shock, or injury to persons, do not use attachments not recommended or sold by the Vanner Power Group. 5. Vanner recommends that all AC and DC electrical wiring be performed by a licensed electrician or a qualified technician to ensure compliance with all applicable national and local wiring regulations.
  • Page 11: Explosive Gas Precautions

    Safety Precautions 8. To reduce the risk of electrical shock, always disconnect the AC and DC connections to the inverter before attempting any maintenance. Simply turning the inverter off does not prevent electrical shock. 9. The inverter must be properly grounded in accordance with local and national codes and ordinances before operation.
  • Page 12: Component Identification And Description Of Operation

    Component Identification and Description of Operation 4 COMPONENT IDENTIFICATION and DESCRIPTION of OPERATION Figure 3 Inverter Top View (1) Top entry for positive DC input cable (2) Top entry for negative DC input cable (3) Top entry for Remote Control Terminal Block IT SERIES Industrial True Sine Wave Inverter Owners Manual...
  • Page 13: Auto Throttle Indicator Light (Volt Guard Feature)

    Feature will insure that the vehicle’s alternator operates at maximum output when needed. The Volt Guard circuit is designed to provide ‘ground control’ for a Bosch relay, Vanner part number 05235 or equal. Use the Bosch relay to operate the automatic throttle, Vanner 73-46 Automatic Throttle or equal.
  • Page 14: Inverter Indicator Light

    Component Identification and Description of Operation (10) Inverter Indicator Light Light Display Description Green Light is OFF Inverter is OFF Solid Green Inverter is ON and is producing AC power Blinking Green Inverter is in Load Demand Mode Figure 4 Inverter Front, Right Side and Bottom View (11) Bottom entry for positive DC input cable (12) Bottom entry for negative DC input cable...
  • Page 15: 15 Amp Ac Output Circuit Breaker

    Component Identification and Description of Operation (16) CB-2 15 Amp AC Output Circuit Breaker CIRCUIT BREAKER CB-2 (bottom breaker) protects the GFCI Receptacle and AC Output AC-2. (17) CB-1 20 or 30 Amp AC Output Circuit Breaker CIRCUIT BREAKER CB-1 (top breaker) protects AC Output AC-1. CB-1 is a 20 amp breaker on models up through 2400 watts.
  • Page 16: Remote Control Terminal Block

    Component Identification and Description of Operation (26) Mounting Brackets ( 2 ) (27) Air Exhaust Vents (28) Side entry for negative DC input cable (29) Side entry for positive DC input cable (30) Positive DC Input Contact (31) Negative DC Input Contact (32) Remote Control Terminal Block A 9-position terminal block is provided for connecting optional, customer supplied remote control and remote display wiring.
  • Page 17: (32.1) Remote On/Off Switch Terminals 1, 2 And 3

    Component Identification and Description of Operation (32.1) Remote ON/OFF Switch Terminals 1, 2 and 3 The IT SERIES Inverter allows four styles of remote control wiring for customers who wish to supply and install a remote control switch or switches. Figure 7 Remote Control Switch Wiring Variations 9 POS BLOCK...
  • Page 18: (32.3) Auto Throttle Control (Volt Guard) Terminal 6

    Use the Bosch relay to control the automatic throttle, Vanner 73-46 Automatic Throttle or equal. Install a ½ amp in-line fuse near the inverter as shown. The sketch below follows the 73-46 Automatic Throttle wiring instructions as for a Dynamic Inverter installation.
  • Page 19: (32.5) Remote Low Battery Warning Terminal 8

    (See also item (5) Low Battery Warning Indicator Light (Low DC Warning) Terminal 8 is designed to provide ground control for a Bosch relay, Vanner part number 05235 or equal, to operate in conjunction with the Low DC Warning Indicator Light. Use the Bosch relay to operate an audible alarm, lights or other warning device.
  • Page 20: Installation And Start-Up

    Installation and Start-up 5 INSTALLATION and START-UP Unpacking the Inverter 1. Inspect the shipping container and equipment for loose or damaged parts. If any damage is found, immediately notify the freight carrier. Inverter Installation Considerations 1. Mounting: Locate a secure, dry, flat horizontal or vertical surface large enough to mount the inverter. The location should be as close to the battery as possible, usually within six feet, but not in the same compartment and should provide adequate ventilation while the inverter is operating.
  • Page 21: Dc Wiring Installation Procedure

    (see figures 1,2,and 3). Two cable clamps and four plastic hole plugs are provided. Bolts are provided for connecting 5/16 diameter ring terminals to the DC Input Contacts. Optional compression lugs (Vanner part no. D08241) are available for cables sizes up to 250 MCM.
  • Page 22 Installation and Start-up 4. Remove the cover plate on the DC cable compartment to expose the positive and negative DC contacts and the Remote Control Terminal Block. 5. Prepare DC cable ends. Use ring terminals or, if using the optional D08241 Compression Lugs, leave the cable ends bare.
  • Page 23: Remote Control Wiring Installation

    Installation and Start-up Remote Control Wiring Installation 1. Refer to the wiring sketches found in the Component Identification and Description of Operation section, item (32), Remote Control Terminal Block. Use fuses where indicated. 2. Use cable clamp provided to secure wiring. A plastic plug is provided for the unused opening. AC Output Wiring Installation Procedure WARNING: Before proceeding with the AC wiring, verify that the inverter is OFF and that the inverter is NOT connected to the battery.
  • Page 24: Preventive Maintenance And Trouble Shooting Procedures

    The following are the most common questions heard by Vanner service professionals. If your situation does not apply to the following categories, please contact your local Vanner Power Group Service Center or the Vanner Power Group Customer Service Department: 1-800-AC-POWER (1-800-227-6937). Please have your model and serial number available when consulting customer service.
  • Page 25 Verify AC load specifications are not exceeded. Problem: Unit does not operate and a “burnt wire” smell emits from inverter. Check: Disconnect AC loads and battery immediately. Unit may require service, contact Vanner service department. IT SERIES Industrial True Sine Wave Inverter...
  • Page 26: Appendix

    3. The product was purchased after January 1, 2000. Vanner does not warrant its products against any and all defects when: defect is a result of material or workmanship not provided by Vanner; normal wear and tear, or defects caused by misuse or use in contrary to instructions supplied, neglect, accident, reversed polarity, unauthorized repairs and/or replacements.
  • Page 27: Gfci Test Record

    Appendix GFCI Test Record For maximum protection against electrical shock hazard, operate the Test Switch on the Ground Fault Circuit Interrupter at least once a month and record the values in this supplied table. Figure 12 GFCI Test Record YEAR 20___ IT SERIES Industrial True Sine Wave Inverter Owners Manual...
  • Page 28: It Series Industrial True Sine Wave Inverter Owners Manual

    IT Series Owner's Manual Vanner Power Group 4282 Reynolds Drive Hilliard, Ohio 43026 1-800-AC POWER (1-800-227-6937) Tel: 614-771-2718 Fax: 614-771-4904 www.vanner.com e-mail: pwrsales@vanner.com Manual Part Number D98494 Printed in USA IT SERIES Industrial True Sine Wave Inverter Owners Manual...