VANNER Owner’s Manual Incorporated TABLE OF CONTENTS 1 INTRODUCTION ................... 3 2 IMPORTANT SAFETY INSTRUCTIONS ..........3 2.1.1 General Safety Precautions ......................3 2.1.2 Precautions When Working With Batteries ................4 3 SPECIFICATIONS AND FEATURES ........... 5 3.1.1 Specifications ..........................5 3.1.2...
Incorporated 1 INTRODUCTION Thank you for purchasing a Vanner 600 Watt VLT SERIES Inverter. We are confident that you will be satisfied with the inverter’s performance and its many features. With proper installation and care, you can look forward to years of service from this high performance product.
VANNER Owner’s Manual Incorporated 2.1.2 Precautions When Working With Batteries If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at least 20 minutes and get medical attention immediately.
VANNER Owner’s Manual Incorporated 3 SPECIFICATIONS AND FEATURES 3.1.1 Specifications Model Number SPECIFICATIONS VLT12-600 VLT24-600 VLTE12-600 VLTE24-600 AC Power Output Rated Continuous Output 600 Watts Surge Rating (3S) A 6.67 3.33 Output Waveform True Sine Wave Total Harmonic Distortion < 3% THD...
VANNER Owner’s Manual Incorporated 3.1.2 Front Panel Pure Sine Wave Inverter INPUT LEVEL LOAD LEVEL FAULT 50Hz AC OUTPUT FREQ. 60Hz 3.1.2.1 ON / OFF Control Switch The ON/OFF Switch must be in the ON position when using Remote Control.
VANNER Owner’s Manual Incorporated 3.1.3 AC Output GFCI Duplex Receptacle The AC output neutral conductor is connected to AC ground and inverter chassis ground inside the inverter. This conforms to National Electrical Code requirements that separately derived AC sources (such as inverter and generators) have their neutral conductors tied to ground in the same way that the neutral conductor from the utility is tied to ground at the AC breaker panel.
Page 8
VANNER Owner’s Manual Incorporated Remote Control via customer-supplied SPST switch: If it is desired to remotely control the inverter from a customer-supplied remote switch, remove the jumper connecting terminals Vout and Vin. Supply a 12v (24v signal on 24v units) continuous signal to terminal Vin to turn the inverter ON. The source of the 12v signal can be battery voltage for single-wire remote control or terminal Vout for two-wire-remote-control.
VANNER Owner’s Manual Incorporated 4 INSTALLATION Inverter Installation Considerations Mounting: Locate a flat secure, dry, horizontal or vertical surface large enough to mount the inverter. The location should be as close to the battery as practical, usually within six feet, but not in the same compartment and should provide adequate ventilation while the inverter is operating.
VANNER Owner’s Manual Incorporated 4.1.1 DC Cable and Fuse Sizing Chart Model Number VLT12-600 VLT24-600 Distance from battery to inverter in feet (Total circuit length is 2 times the distance.) Wire Size 13.5 10.0 16.0 Fuse Rating 80 Amp 60 Amp...
VANNER Owner’s Manual Incorporated 5 TROUBLESHOOTING WARNING! Do not open or disassemble the Inverter. Attempting to service the unit yourself may result in a risk of electrical shock or fire, and will void warranty. Problems and Symptoms Possible Cause Solutions No AC output voltage accompanied by the following Power Status LED flash pattern.