Arming And Disarming; Regular Arming Switches To Stay Arming; Regular Arming Switches To Force Arming; Stay Arming Switches To Force Arming - Paradox Magellan MG-6060 Reference And Installation Manual

All-in-one wireless security system v1.0
Hide thumbs Also See for Magellan MG-6060:
Table of Contents

Advertisement

Regular Arming Switches to Stay Arming

Section [092]: Option [4]
Option [4] OFF = Switch to Stay arming disabled (default)
Option [4] ON = Switch to Stay arming enabled
If a user Regular arms the system, but does not exit through
(open and close) an Entry Delay zone during the Exit Delay, the
console can be programmed to switch from Regular arming to
Stay arming.

Regular Arming Switches to Force Arming

Section [092]: Option [5]
Option [5] OFF = Regular arming switches to Force arming
disabled
Option [5] ON = Regular arming switches to Force arming
enabled (default)
With this feature enabled, the console will always Force arm
instead of Regular arm when a valid User code is entered. In
installations where the User must always Force arm when
leaving the protected area, this feature allows users to Force arm
after entering their User code.

Stay Arming Switches to Force Arming

Section [092]: Option [6]
Option [6] OFF = Stay arming switches to Force arming disabled
(default)
Option [6] ON = Stay arming switches to Force arming enabled
With this feature enabled, the console will always Force arm and
Stay arm when a valid User code is entered even if there are
perimeter zones open.

Timed Auto-Arming

Section [092]: Option [1]
Option [1] OFF = Timed Auto-arming disabled (default)
Option [1] ON = Timed Auto-arming enabled
The Magellan system can be programmed to arm every day at
the time specified by the Auto-arm Timer (see Auto-arm Timer
on page 20). The following also apply:
The Auto-arming options (Auto-Arming Options on page 20)
determine the arming method.
Any open zones detected when the system is Auto-armed
will be bypassed regardless of their definition (except 24hr.
zones).
The console will enter a 60-second Exit Delay period before
arming the system. At this point, Auto-arming can be
cancelled by entering a valid access code.
Once the system has successfully armed, the console can
transmit the Timed Auto-Arming report code programmed in
section [124].
Example: To automatically arm the system everyday at 6:15PM,
enable section [092] option [1] to activate Timed Auto-arming
and then key in 18:15 into section [085].
20

Arming and Disarming

Auto-arm Timer
Section [085]
Program the time (use the 24-hour clock i.e. 6:30PM = 18:30)
that you wish the console to attempt to arm the system and/or
send the Late to Close report code.

No Movement Auto-Arming

Section [092]: Option [2]
Option [2] OFF = No Movement Auto-arming disabled (default)
Option [2] ON = No movement Auto-arming enabled
If no movement occurs in a zone's protected area for the period
specified by the No Movement Timer (see below), the console
can automatically arm the system.
The Auto-arming option (Auto-Arming Options on page 20)
determines the system's arming method.
Any open zones detected when the system is Auto-armed
will be bypassed regardless of their definition (except 24hr.
zones).
Upon arming, the console will transmit the No Movement
report code if programmed in section [124].
Regardless of whether the system was successfully armed
or not, the console will always transmit the No Movement
report code if programmed in section [124].
If No Movement Auto-arming is disabled, the console will
still send the No Movement report code at the time specified
by the No Movement Timer.
Example: To arm the system whenever there is no movement for
a period of 4 hours, enable section [092] option [2] (No
Movement Auto-arming) and then in section [064], enter 016 (16
x 15min. = 240min. = 4 hours).
No Movement Timer
Section [064]: 001 to 255 x 15 minutes; 000 = Disabled; Default
= 000
Program the interval of time without movement you wish the
console to wait before arming and/or sending the No Movement
report code. If No Movement Auto-arming is disabled, the
console can still send the No Movement report code when no
movement has been detected for the period specified by the No
Movement Timer.

Auto-Arming Options

Section [092]: Option [3]
Option [3] OFF = Auto-arm system using Regular arm (default)
Option [3] ON = Auto-arm system using Stay
When using Timed Auto-arming (page 20) or No Movement
Auto-Arming (page 20), the console can Regular or Stay arm the
system.
Reference & Installation Manual

Hide quick links:

Advertisement

Table of Contents
loading