Arming And Disarming Options; Switch To Stay Arming If No Entry Delay Is Opened; When Delay Zone Is Bypassed Follow Zones Become Entry Delay 2; Regular Arming Switches To Force Arming - Paradox Magellan MG5050E Installation Manual

32-zone wireless & 4 to 32-zone expandable security systems
Hide thumbs Also See for Magellan MG5050E:
Table of Contents

Advertisement

Arming and Disarming Options

Switch to Stay Arming if no Entry Delay is opened

Section [741]: Partition 1, Section [742] = Partition 2
Option [5] OFF= Switch to Stay Arming Disabled (default)
Option [5] ON= Switch to Stay Arming Enabled
If a user Regular arms a partition, but does not exit through (open and close) an entry delay zone during the exit delay, the control panel can be programmed to
switch from Regular arming to Stay arming.

When Delay Zone is bypassed Follow Zones become Entry Delay 2

Section [741]: Partition 1, Section [742] = Partition 2
Option [6] OFF= Follow zones become entry delay 2 when delay zone is bypassed disabled (default)
Option [6] ON= Follow zones become entry delay 2 when delay zone is bypassed enabled
If a user has an entry point defined as a delay, and a motion detector set as a follow zone, this option allows the user to bypass a delay zone so that the motion
detector becomes an entry delay 2 zone. For example, if a user has a malfunctioning door contact, they can bypass the delay zone and have the motion detector
become an entry delay 2 zone so that they have sufficient time to disarm the system. All follow zones become entry delay 2 if at least one delay zone is bypassed.

Regular Arming switches to Force Arming

(Not to be used with UL Installations)
Section [704]: Arming/Disarming Options
Option [1] OFF= Regular Arming Switches to Force Arming Disabled
Option [1] ON= Regular Arming Switches to Force Arming Enabled (default)
With this feature enabled, the control panel will always Force arm (if a force-enabled zone is open, See "Force Zones" on page 34) instead of Regular arm when a
valid user access code with the Force Arming Option is entered.

Stay Arming switches to Stay Force Arming

(Not to be used with UL Installations)
Section [704]: Arming/Disarming Options
Option [2] OFF= Stay Arming Switches to Stay Force Arming Disabled
Option [2] ON= Stay Arming Switches to Stay Force Arming Enabled (default)
With this feature enabled, the control panel will always Stay Force arm (if a force-enabled zone is open, See "Force Zones" on page 34) instead of Stay arm when a
valid user access code with the Force Arming Option is entered.

Sleep Arming switches to Sleep Force Arming

(Not to be used with UL Installations)
Section [704]: Arming/Disarming Options
Option [3] OFF= Sleep Arming Switches to Sleep Force Arming Disabled
Option [3] ON= Sleep Arming Switches to Sleep Force Arming Enabled (default)
With this feature enabled, the control panel will always Sleep Force arm (if a force-enabled zone is open, See "Force Zones" on page 34) instead of Sleep arm when a
valid user access code with the Force Arming Option is entered.

Restrict Arming on Battery Failure

Section [703]: Arming/Disarming Options
Option [5] OFF= Permit arming on battery failure (default)
Option [5] ON= Restrict arming on battery failure
If this option is enabled, the control panel will not arm the system if the control panel detects that the backup battery is disconnected, that its fuse is blown, or that
the battery voltage drops to less than 10.5V. The control panel will not arm the system until all battery trouble conditions are rectified.

Restrict Arming on Tamper Failure

Section [703]: Arming/Disarming Options
Option [6] OFF= Permit arming on tamper failure (default)
Option [6] ON= Restrict arming on tamper failure
If this option is enabled, the control panel will not arm the system if the control panel detects a tamper trouble on one or more zones. The control panel will not arm
the system until all tamper trouble conditions are rectified.
WARNING: This feature will not function if the tamper recognition options (See "Tamper Recognition" on page 47) are disabled or whenever the
tampered zone is bypassed and the tamper bypass options have been enabled (See "Tamper Bypass Options" on page 47).
44
Magellan & Spectra SP • Installation Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents