Console Telephone Numbers - Paradox Magellan MG-6060 Reference And Installation Manual

All-in-one wireless security system v1.0
Hide thumbs Also See for Magellan MG-6060:
Table of Contents

Advertisement

Auxiliary Panic: Panic keys [4] and [6] (page 23) or the
appropriate button(s) on a remote control (page 18) have
been pressed.
Fire Panic: Panic keys [7] and [9] (page 23) or the
appropriate button(s) on a remote control (page 18) have
been pressed.
Recent Closing: Reports when an alarm is generated after
arming the system within period defined by the Recent
Close Delay (see page 28).
Section [140]
Auto-zone Shutdown: A zone communicates more than the
programmed number of transmissions in a single armed
period (see page 15).
Duress: A Duress access code is keyed in (see page 12).
Paramedical alarm
Future use
Zone Tamper Report Codes
Section [141] to [144]
A report code can be programmed for each of the 16 available
zones. Whenever a tamper or wire fault occurs on a zone, the
Magellan console can send the appropriate report code to the
central station identifying which zone was tampered.
If Tamper Recognition (see page 22) is disabled, the
console will not report the occurrence of any tampers,
wire faults or tamper restores.
Zone Tamper Restore Report Codes
Sections [145] to [148]
A report code can be programmed for each of the 16 available
zones. Whenever a tampered zone is restored, the Magellan
console can send the appropriate report code to the central
station identifying which zone has been restored.
If Tamper Recognition (see page 22) is disabled, the console
will not report the occurrence of any tampers, wire faults or
tamper restores.
System Trouble Report Codes
Section [149] to [151]
Whenever the system generates one of the instances listed
below, the console can send the appropriate report code to the
central station identifying the type of system trouble.
Section [149]
Console Tamper: A tamper has been detected on the
console itself (see Console Tamper Supervision on page
31).
AC Failure: Magellan has detected a loss of AC power.
Transmission of this report code can be delayed (see Power
Failure Report Delay on page 29).
Battery Failure: The backup battery is disconnected or
battery voltage is ≤ (less than or equal to)6.9V.
Timer Loss: The console has detected a loss in time or clock
failure.
Section [150]
Future use
Fail To Communicate: The Magellan console has failed all
attempts to communicate with the central station. The report
code will be transmitted upon the next successful attempt.
Paradox Magellan Systems
Wireless Low Battery: The battery voltage of an Omnia
wireless transmitter (motion detector or contact switch) has
dropped below recommended limits.
Tx Supervision Loss: Check-in Supervision (page 22) has
been enabled and a transmitter is no longer communicating
with the system.
Section [151]
Future use
Future use
Future use
Future use
System Trouble Restore Codes
Sections [152] to [154]
Whenever the system restores one of the troubles listed in
sections [149] and [150] (see System Trouble Report Codes on
page 25), the Magellan console can send the appropriate report
code to the central station identifying the type of system trouble
restored. If Telephone Line Monitoring is enabled (see page 28),
use the first two digits to program a TLM Restore report code
that the console can transmit.
Special Reporting Codes
Sections [155] and [156]
Whenever the system generates one of the instances listed
below, the Magellan console can send the appropriate report
code to the central station identifying the type of system
occurrence.
Section [155]
Cold Start: The console was completely shutdown (no
battery, no AC) and then was restarted.
Test Report: A test report has been generated automatically
(see page 29).
Future use
WinLoad Logout: The console has ended communication
with WinLoad.
Section [156]
Installer logon: Installer has entered the programming
mode.
Installer Logout: Installer has exited the programming mode.
Closing Delinquency: The last time the system was armed is
greater than the programmed Closing Delinquency timer
(page 21).
Future use

Console Telephone Numbers

Magellan can dial up to two different central station telephone
numbers and one Pager telephone number. You can enter any
digit from 0 to 9 and any special keys or functions (see Table 8
on page 26) up to a maximum of 32 digits. If the number is less
than 32 digits, press the left [
message.
] key (
OK
) to save the
ACTION
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents