Start-Up/Hot Water Operation - Graco AquaMax 3540GHW Instructions Manual

Hot water pressure washer
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

Start-up/Hot Water Operation

Refer to the "Safety Precautions" pgs. 3-5 before start-
ing the unit.
Locate the Safety Decals on your unit and heed their
warnings.
Never look directly into the nozzle. High pressure water
creates a risk of severe injury.
1. Follow the steps outlined for "Start-up/Cold Water
Operation".
2. Move the Burner Switch to the ON position. On initial
start-up, water will begin turning hot in approximately
20 seconds and will reach maximum temperature in
approximately 2-1/2 minutes, provided the trigger
remains squeezed. The burner will stop firing when
the trigger is released.
Note: While spraying, it is normal for the burner to fire
intermittently. The high-limit switch will cause combus-
tion to cease when the temperature of the discharged
water exceeds the maximum temperature setting of the
switch. Combustion will begin again when the temper-
ature drops below the minimum setting.
14
The water temperature could become very hot dur-
ing hot water operation. Be cautious when adjusting
pressure or controlling the trigger gun/dual lance
assembly to avoid the possibility of burns.
NOTICE
Do not allow spray pattern to remain on a fixed area
for an extended period of time. Possible damage
may occur to the area.

Advertisement

Table of Contents
loading