MD Function's Prerequisite when using SCU-VAC/VAC1 (SCB-3000) :
Set Alarm Out of Camera Setting – Open Camera Menu – Special
Intelligence menu to ON.
For SCU-VAC/VAC1, the MD function will be activated 1.5 seconds after you
have moved to the preset position.
However, SCU-VAC1 can enable MD after a maximum of 25 seconds depending on the Zoom/Focus setting.
For SCB-3000
- The MD function will operate normally after 1.5 seconds of system stabilization and 5 seconds of intelligence
stabilization.
- If using Group SEQ, set the dwell time to at least 8 seconds.
MD restrictions according to the box camera module
For SCU-VAC/VAC1, the MD function is the only after-action.
- SHC-745 : Only motion detection is available.
- SCB-3000 : If you come to use MD at the preset point while in intelligence mode, the current Intelligence mode will be
deactivated.
- SCB-4000 : If you come to use MD at the preset point while using "Advanced" of the intelligence functions, the current
"Advanced" function will stay active.
The PTZ menu may be displayed "PT", depending on the lens.
Preset Edit
[001]
PTZ
000/000/1X
After Action
OFF
English - 49