Campbell Hausfeld Vertical Operating Instrctions

Campbell Hausfeld Vertical Operating Instrctions

Stationary air compressor vertical models
Table of Contents

Advertisement

Available languages

Available languages

See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Stationary
Air Compressor
Description
Air compressor units are intended to
provide compressed air to power
pneumatic tools and operate spray guns.
The pumps supplied are oil lubricated. A
small amount of oil carryover is present
in the compressed air stream.
Applications requiring air free of oil or
water should have the appropriate filter
installed. The air compressor unit must
be mounted as described in the
instructions on a solid floor. Any other
use of these units will void the warranty
and the manufacturer will not be
responsible for problems or damages
resulting from such misuse.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, may
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2011
Figure 1
tighten fittings, bolts, etc., before
putting unit into service.
Do not operate
WARNING
!
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
pumping system, the following safety
precautions must be observed at all
times:
1. Read all manuals
included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the equipment.
2. Follow all local electrical and safety
codes as well as in the United
States, the National Electrical Codes
(NEC) and Occupational Safety and
Health Act (OSHA).
DANGER
!

Breathable Air Warning

This compressor/pump is NOT
equipped and should NOT be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, you must fit
the air compressor/pump with
suitable in-line safety and alarm
equipment. This additional
equipment is necessary to properly
filter and purify the air to meet
minimal specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties are void, and Campbell
Hausfeld disclaims any liability
whatsoever for any loss, personal
injury or damage.
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
MANUAL
5. Wear safety glasses and
use hearing protection
when operating the
unit.
6. Do not stand on or use the unit as
a handhold.
7. Before each use, inspect compressed
air system and electrical
components for signs of damage,
Vertical Models
IN227706AV 2/11

Advertisement

Table of Contents
loading

Summary of Contents for Campbell Hausfeld Vertical

  • Page 1: Breathable Air Warning

    See Warranty on page 8 for important information about commercial use of this product. Operating Instructions Vertical Models Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Page 2: General Safety

    Operating Instructions General Safety tank and drops to a preset low level, DANGER (Con’t) the pressure switch automatically turns deterioration, weakness or leakage. Never attempt to repair or the motor back on. In the "off" Repair or replace defective items modify a tank! Welding, position, the compressor will not before using.
  • Page 3: Electrical Installation

    Vertical Models Introduction PIPING This compressor is (Con’t) WARNING extremely top Never use plastic WARNING heavy. The unit must be bolted to the Check valve - One-way valve that (PVC) pipe for floor with isolation pads or secured allows air to enter the tank, but compressed air.
  • Page 4 Operating Instructions Installation (Con’t) Fused Breaker Or Disconnect Line Motor Electrical Connection UNITS WITH LINE CORDS ONLY 240V NOTE: 120 volt, 15 amp units can be COIL operated on a 120 volt 15 amp circuit Pressure Pressure under the following conditions: OVER- Thermal Switch...
  • Page 5: Maintenance

    Vertical Models Maintenance Dipstick Breather MOISTURE IN COMPRESSED AIR WARNING Moisture in compressed air will form Full into droplets as it comes from an air Add Oil Disconnect, tag and lock compressor pump. When humidity is out power source, then...
  • Page 6: Maintenance Schedule

    Operating Instructions Maintenance MAINTENANCE SCHEDULE (Con’t) TO ADJUST DRIVE BELT: Operation Daily Weekly Monthly 3 Months 1. Remove belt guard. ● Check Oil Level 2. Loosen the four fasteners holding ● Drain Tank the motor to the baseplate. ● Check Air Filter ●...
  • Page 7 Vertical Models Troubleshooting Chart (Continued) Symptom Possible Cause(s) Corrective Action Excessive noise 6. Noisy check valve in 6. Replace. (knocking) compressor system Do not disassemble check valve with DANGER Continued air pressure in tank 1. Worn piston rings Large quanity of oil in the 1.
  • Page 8 2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400 3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld compressor.
  • Page 9: Généralités Sur La Sécurité

    Généralités sur la DANGER Danger en existance seront annulées, et indique Sécurité Campbell Hausfeld nie toute une situation hasardeuse imminente responsabilité pour n’importe qui RÉSULTERA en perte de vie ou Puisque le compresseur d’air et les quelle perte, blessure ou dommage.
  • Page 10: Précautions De Pulvérisation

    Instructions D’Utilisation Généralités sur la de service maximum. Ne pas faire Introduction fonctionner avec un manostat ou Sécurité (Suite) Se référer à la Figure 2. soupapes pilotes réglés au delà de la pression de fonctionnement maximum. détérioration, faiblesse ou fuites INSTALLATION D’UNE SOUPAPE 13.
  • Page 11 Modèles Verticaux Introduction MONTAGE (Suite) ATTENTION Ne jamais Régulateur - Le régulateur contrôle la utiliser quantité de pression d’air échappée à les palettes en bois d’expédition pour la sortie de tuyau (Vendu séparément). le montage du compresseur. Soupape de Sûreté ASME - Cette MONTAGE AU PLANCHER soupape laisse échapper l’air (Tous les modèles)
  • Page 12: Installation De Fils

    Instructions D’Utilisation Installation (Suite) Interrupteur à Fused Breaker Moteur Ligne fusibles ou Or Disconnect Line Motor INSTALLATION DE FILS DIRECTE sectionneur SEULEMENT 240V INSTALLATION DE FILS COIL Les codes locaux concernant Manostat Pressure Pressure Appareils l’installation de fils varient d’endroit Manostat OVER- Thermal...
  • Page 13: Montage

    Modèles Verticaux 1. Enlever le reniflard et remplir la Montage Reniflard de la Dipstick pompe d’huile jusqu’au niveau reglette-jauge Breather correct. Se référer à la section de QUINCAILLERIE ADDITIONNELLE Plein graissage. Full EXIGÉE Ajoutez l’huile Add Oil 2. Ouvrir le robinet de purge de Acheter des tuyaux, un régulateur et Ajoutez réservoir.
  • Page 14: Courroie D'entrainement

    Instructions D’Utilisation Entretien HORAIRE D’ENTRETIEN (Suite) Hebdo- DANGER Opération Quotidien madaire Mensuel 3 Mois ● Vérifier le niveau d’huile trifouiller avec cette soupape. Vérifier ● Purger le réservoir cette soupape de temps en temps. S’il ● y a des fuites d’air après que l’anneau Vérifier le filtre à...
  • Page 15 Modèles Verticaux Guide De Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesure Corrective Bruit excessif 5. Piston frappe la plaque de 5. Enlever la tête du compresseur et la plaque de soupape et inspecter (cognement) soupape pour de l’encrassement charbonneux ou autre matières étranges sur Suite la partie supérieure du piston.
  • Page 16 A. Fournir une preuve d’achat datée et un état d’entretien. B. La livraison ou expédition des compresseurs portatifs ou des pièces détachées au Centre De Service Autorisé Campbell Hausfeld le plus près. Frais de transport, si applicables, sont la responsabilité de l’acheteur.
  • Page 17 Esta información se la Campbell Hausfeld. no asumirá tuercas y conexiones, antes de usarlo. suministramos como medida de NINGUNA responsabilidad por SEGURIDAD y para EVITAR PROBLEMAS pérdidas, heridas personales o daños.
  • Page 18 Manual de Instrucciones operativa. No opere con el presostato o Introducción Generales Seguridad la válvula piloto ajustados a presiones (Continuación) más elevadas de la presión máx. Vea la Figura 2. operativa. PARA INSTALARLE UNA VALVULA componentes eléctricos para ver si 13.
  • Page 19: Instalación

    Modelos Verticales Introducción INSTALACION EN EL PISO No use ADVERTENCIA tornillos (Todas las Unidades) (Continuación) de fiador para fijar el compresor a DEBERA atornillar las patas a una muros en seco. Éstos no son lo Válvula de Seguridad ASME - Esta superficie plana y nivelada, tal como un suficientemente resistentes para válvula libera el aire automáticamente...
  • Page 20 Manual de Instrucciones Instalación (Continuación) Fused Breaker Cortacircuito o Línea Or Disconnect Line Motor Interruptor SOLO LAS UNIDADES CON CONEXIONES PERMANENTES 240V COIL Si no PRECAUCION Unidades instala el Pressure Presostato Pressure Presostato OVER- sistema de alambrado adecuado podría Thermal Térmicas Switch Switch...
  • Page 21: Mantenimiento

    Modelos Verticales Ensamblaje 2. Abra la válvula de drenaje del Dipstick Varilla del Breather tanque. Abra la llave de salida para respiradero permitir el flujo de aire. ACCESORIOS ADICIONALES Lleno Para añadirle Full 3. Mueva la palanca o perilla del NECESARIOS Add Oil el aceite...
  • Page 22: Guía De Diagnóstico De Averías

    Manual de Instrucciones Mantenimiento MANTENIMIENTO Diaria- Semanal- Mensual- Trimestral- (Continuación) Servicio Necesario mente mente mente mente Si la PRECAUCION ● Mida el Nivel de Aceite válvula ● Drene el Tanque de seguridad se hace funcionar con ● Chequée el Filtro de Aire presión de aire en el tanque, se liberará...
  • Page 23 Modelos Verticales Guía de Diagnóstico de Averías (Continuación) Problema Posible(s) Causa(s) Acción a Tomar Ruido excesivo (golpeteo) - 6. Reemplácela. 6. Válvula de verificación ruidosa en Continuación el sistema del compresor PELIGRO No desarme la válvula de verificación con presión de aire en el tanque. 1.
  • Page 24 1. DURACIÓN: A partir de la fecha de compra por el comprador original tal como se especifica a continuación: Un Año, Dos Años, Tres Años, Cuatro Años o Cinco Años como se indica en la etiqueta de características del producto. 2. QUIEN OTORGA ESTA GARANTÍA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3.

Table of Contents