Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Air compressor units are intended to
provide compressed air to power
pneumatic tools and operate spray guns.
The pumps supplied are oil lubricated. A
small amount of oil carryover is present
in the compressed air stream.
Applications requiring air free of oil or
water should have the appropriate filter
installed. The air compressor unit must
be mounted as described in the
instructions on a solid floor. Any other
use of these units will void the warranty
and the manufacturer will not be
responsible for problems or damages
resulting from such misuse.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, may
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
© 2002 Campbell Hausfeld
Stationary

Air Compressor

Figure 1
tighten fittings, bolts, etc., before
putting unit into service.
Do not operate
WARNING
!
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
pumping system, the following safety
precautions must be observed at all
times:
1. Read all manuals
included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the equipment.
2. Follow all local electrical and safety
codes as well as in the United
States, the National Electrical Codes
(NEC) and Occupational Safety and
Health Act (OSHA).
1
!

Breathable Air Warning

This compressor/pump is NOT
equipped and should NOT be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, you must fit
the air compressor/pump with
suitable in-line safety and alarm
equipment. This additional
equipment is necessary to properly
filter and purify the air to meet
minimal specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties are void, and Campbell
Hausfeld disclaims any liability
whatsoever for any loss, personal
injury or damage.
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
5. Wear safety glasses and
MANUAL
use hearing protection
when operating the
unit.
6. Do not stand on or use the unit as
a handhold.
7. Before each use, inspect compressed
air system and electrical
components for signs of damage,
DANGER
IN227705AV 12/02

Advertisement

Table of Contents
loading

Summary of Contents for Campbell Hausfeld VS260000KB

  • Page 1: Air Compressor

    States, the National Electrical Codes air system and electrical carefully for any damage that may have (NEC) and Occupational Safety and components for signs of damage, occurred during transit. Make sure to Health Act (OSHA). © 2002 Campbell Hausfeld IN227705AV 12/02...
  • Page 2: General Safety

    Operating Instructions Stationary Air Compressor pressure reaches the maximum preset General Safety DANGER (Con’t) pressure. After air is used from the Never attempt to repair or deterioration, weakness or leakage. tank and drops to a preset low level, modify a tank! Welding, Repair or replace defective items the pressure switch automatically turns drilling or any other...
  • Page 3: Electrical Installation

    Operating Instructions Vertical Models (Part number MP3445 available PIPING Introduction separately). Do not draw bolts tight. Never use plastic WARNING (Continued) Allow the pads to absorb vibrations. A (PVC) pipe for flexible coupling should be installed compressed air. Serious injury or death hot during use.
  • Page 4 Operating Instructions Stationary Air Compressor Installation (Con’t) Fused Breaker Or Disconnect Line Motor for thermal protection (See Figure 4). Electrical Connection 240V UNITS WITH LINE CORDS ONLY COIL Pressure NOTE: 120 volt, 15 amp units can be Pressure OVER- Thermal Switch LOAD Switch...
  • Page 5: Operation

    Model Approx. Oil Capacity power cord. Move pressure switch and cannot be actuated by the ring, the to the AUTO position to run the VS260000KB 6 oz safety valve must be replaced. unit. A large amount of VT470200KB 11.5 oz...
  • Page 6: Maintenance Schedule

    Operating Instructions Stationary Air Compressor MAINTENANCE SCHEDULE Maintenance (Con’t) Operation Daily Weekly Monthly 3 Months TO ADJUST DRIVE BELT: Check Oil Level 1. Remove belt guard. Drain Tank 2. Loosen the four fasteners holding Check Air Filter the motor to the baseplate. Check Safety Valve 3.
  • Page 7 Operating Instructions Vertical Models Troubleshooting Chart (Continued) Symptom Possible Cause(s) Corrective Action 6. Noisy check valve in Excessive noise 6. Replace. compressor system (knocking) Do not disassemble check valve with DANGER Continued air pressure in tank Large quanity of oil in the 1.
  • Page 8: Limited Warranty

    B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
  • Page 9: Généralités Sur La Sécurité

    DANGER Danger indique en existance seront annulées, et Sécurité une situation hasardeuse imminente Campbell Hausfeld nie toute qui RÉSULTERA en perte de vie ou responsabilité pour n’importe Puisque le compresseur d’air et les blessures graves. quelle perte, blessure ou dommage.
  • Page 10 Instructions D’Utilisation Compresseur D’Air Stationnaire Généralités sur la de service maximum. Ne pas faire Introduction Sécurité fonctionner avec un manostat ou (Suite) soupapes pilotes réglés au delà de la Se référer à la Figure 2. pression de fonctionnement maximum. avant chaque utilisation. Réparer INSTALLATION D’UNE SOUPAPE 13.
  • Page 11 Instructions D’Utilisation Modèles Verticaux MONTAGE Introduction (Suite) ATTENTION Ne jamais utiliser soulage les démarrages du moteur sous les palettes en bois d’expédition pour charge. le montage du compresseur. Régulateur - Le régulateur contrôle la MONTAGE AU PLANCHER quantité de pression d’air échappée à (Tous les modèles) la sortie de tuyau (Vendu séparément).
  • Page 12 Instructions D’Utilisation Compresseur D’Air Stationnaire Installation Interrupteur à Fused Breaker (Suite) Moteur Ligne fusibles ou Or Disconnect Line Motor sectionneur INSTALLATION DE FILS DIRECTE SEULEMENT 240V l’installation de fils varient d’endroit en COIL endroit. Les fils d’alimentation, fiches Manostat Pressure Appareils Pressure et le protecteur doivent être classifiés...
  • Page 13: Montage

    Mettre le Modèle Capacité d’huile approx. Installation levier du manostat à la position AUTO (Suite) pour faire fonctionner le modèle. VS260000KB 0,18 L VT470200KB 0,34 L terre de la fiche et au corps métallique du manostat. VT470000KB...
  • Page 14: Courroie D'entrainement

    Instructions D’Utilisation Compresseur D’Air Stationnaire HORAIRE D’ENTRETIEN Entretien (Suite) Hebdo- Opération Quotidien madaire Mensuel 3 Mois quantité d’air sera relâchée rapidement Vérifier le niveau d’huile si cette soupape est actionnée lorsque Purger le réservoir le réservoir est pressurisé. Vérifier le filtre à air 2.
  • Page 15 Modèles Verticaux Instructions D’Utilisation Guide De Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesure Corrective Bruit excessif la partie supérieure du piston. Remplacer la culasse et la plaque de (cognement) soupape et utiliser un nouveau joint d’étanchéité. Voir la section de Suite Graissage pour l’huile recommandée.
  • Page 16 8. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Fournir une preuve d’achat datée et un état d’entretien. B. La livraison ou expédition des compresseurs portatifs ou des pièces détachées au Centre De Service Autorisé Campbell Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
  • Page 17 Esta información se la Campbell Hausfeld. no asumirá tuercas y conexiones, antes de usarlo. NINGUNA responsabilidad por suministramos como medida de pérdidas, heridas personales o daños.
  • Page 18 Manual de Instrucciones Compresores de Aire Estacionarios operativa. No opere con el presostato o Introducción Generales Seguridad (Con’t) la válvula piloto ajustados a presiones más elevadas de la presión máx. componentes eléctricos para ver si Vea la Figura 2. operativa. están dañados, deteriorados o hay PARA INSTALARLE UNA VALVULA 13.
  • Page 19: Instalación

    Manual de Instrucciones Modelos Verticales En algunos modelos de 30 galones se No use Introducción (Con’t) ADVERTENCIA proporciona un cable de pared el cual tornillos debe ser instalado. Si la unidad no se de fiador para fijar el compresor a Válvula de Seguridad ASME - Esta asegura a la pared con un cable, muros en seco.
  • Page 20 Manual de Instrucciones Compresores de Aire Estacionarios Instalación (Continuación) Fused Breaker Cortacircuito o Línea Or Disconnect Line Motor Interruptor SOLO LAS UNIDADES CON CONEXIONES PERMANENTES 240V Si no COIL PRECAUCION instala el Unidades Pressure Presostato Pressure Presostato sistema de alambrado adecuado podría OVER- Térmicas Thermal...
  • Page 21: Mantenimiento

    Cap. Aprox. de Aceite seguridad se hace funcionar con presión 3. Mueva la palanca o perilla del de aire en el tanque, se liberará una gran VS260000KB 0,18 L presostato a la posición OFF y cantidad de aire que se encuentra en enchufe el cordón de alimentación.
  • Page 22 Manual de Instrucciones Compresores de Aire Estacionarios MANTENIMIENTO Mantenimiento Diaria- Semanal- Mensual- Trimestral- Servicio Necesario (Continuación) mente mente mente mente Mida el Nivel de Aceite debe ser sólo una 12,7 mmm (1/2”) al Drene el Tanque aplicarle una fuerza de 2,27 kg entre la Chequée el Filtro de Aire polea del motor y el cabezal (Vea la Chequée la Válvula de Seguridad...
  • Page 23 Manual de Instrucciones Modelos Verticales Guía de Diagnóstico de Averías (Continuación) Problema Posible(s) Causa(s) Acción a Tomar Aceite excesivo en el aire 1. Reemplácelos con aros nuevos. Mantenga el nivel de aceite y 1. Aros del émbolo desgastados de descarga. NOTA: En un cambie el aceite con más frecuencia.
  • Page 24: Garantía Limitada

    Estándard (Standard Duty) - Un año; Productos Resistentes (Serious Duty) -Dos años; Productos Robustos (Extreme Duty) - Tres años; Serie Modelo Maxus - Cinco años. 2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3.

This manual is also suitable for:

Vt470200kbVt470000kb

Table of Contents