INSTALLATION
11.6
Wiring diagram
6
X31
5
X40
4
X32
3
X90
X30
X17
2
X16
1
T°C
X2
20
19
18 17 16 15 14 13 12 11
10 9 8 7 6 5 4 3 2 1
1
2
3
4
3
2 1
4
5
6
1 2 3
D
19
18
17
Key
2
Control accessories connector
3
Reserved for future use
4
Location for 24V option card
5
Location for external programmer
6
User interface
7
Fuse 2A
8
Connector for 230 V option
9
Main supply 230V
10 Pump
- 24 -
X51
X2
20
19
18 17 16 15 14 13 12 11
10 9 8 7 6 5 4 3 2 1
1
2
3
4
5
6
10
11
12
13
14
15
X18
X18
X20
X17
NTC
24 V
Ebus
1
2
10
11
1 2
16
X14
7
8
9
1 2
16
17
18
3 4
X21
M
X20
3
4
5
6
7
8
9
12
13
14
15
16
17
18
5
4
3
2 1
9
8
...
2 1
1
T
M
15
14
12 Heating outlet temperature sensor
13 Heating return temperature sensor
14 Gas valve
15 Fan
16 Thermal fuse
17
18
19 Water pressure sensor