Trux Configuration Guide
3.3.1.2 General Settings Tab
The General Settings tab provides configuration options for the COM1, COM2 and Multipurpose
Connector ports, Startup and Shutdown options and configuration of the optional defroster.
After making any desired changes, click Apply to apply the new changes or OK to apply the changes and
dismiss the Trux Manager screen.
COM1 Power
Enable 5VDC power on COM1 pin 9 to power external 5V devices with a maximum power consumption
of 2,5W, 500mA.
If you want the external device to be powered in suspend mode or when the terminal runs on its UPS
battery, you must also select those options.
COM2 Power
Enable 12VDC power on COM2 pin 9 to power external 12V devices with a maximum power
consumption of 6W, 500mA. Options are the same as for COM1.
Mult Purpose Connector
Enable 12VDC power on Multi Purpose Connector COM4 pin 9 to power external 12V devices. Same
power consumption and options as COM2.
COM4 is enabled by default but can be de-selected if necessary.
E-EQ-TRUXCONFIG-D-ARC
Figure 13 Tx700 Trux Manager General Settings Tab
Trux Manager
33