Ctrl (Rs232 Control) - Red Epic Epic-M Operation Manual

Digital camera professional
Hide thumbs Also See for Epic-M:
Table of Contents

Advertisement

CTRL (RS232 CONTROL)

A 4-pin LEMO connector supports RS232 remote control for stereoscopic camera image capture, and
third party metadata ingest applications. Supported command protocol is available on request.
The shutter Sync Output signal acts as an immediate response hardware tally of a scan. This is useful for
3D or motion control applications where a slave camera or lighting device needs to be synchronized to a
master camera.
Alternatively, this output pin may be used as a GPO (General Purpose Output) tally, whose function is
programmed in the USER KEYS menu. Default is Record Tally.
Figure 23: View into camera CTRL (RS232 Control) Interface connector
PIN
1
2
3
4
NOTE: When active, the GPO tally presents 3.3V @ 0.04 Amps maximum between pins 1 and 3.
NOTE: A pre-fabricated CTRL interface cable is available from RED Digital Cinema.
P/N 790-0152 – RS232 – Camera to DB-9 – 3 ft. (1m)
DB-9 Pin 1:
Shutter Sync / GPO
DB-9 Pin 2:
RS232 Tx
DB-9 Pin 3:
RS232 Rx
DB-9 Pin 4:
Ground
138
138
Mating Connector: LEMO FGG.00.304.CLAD27Z
SIGNAL
GROUND
232 RX
SS/GPO
Shutter Sync / GPO Output
232 TX
©2011 RED.COM INC.
DESCRIPTION
Common Ground
RS232 RX
RS232 TX
Version 1.6.46
NOVEMBER 17, 2011

Advertisement

Table of Contents
loading

This manual is also suitable for:

Epic-x

Table of Contents