4
Figure 4. Mounting Brackets Required for Changing Projector Configuration
9. Flip the PHM so the lens is facing up in the
lens vertical configuration. (Figure 5.)
10. Tilt the PHM up slightly and slide it
forward until it engages with the two tabs
on the front mounting bracket. (Figure 6.)
11. Lower the PHM into place and tighten the
2 screws on the mounting bracket to
secure. (Figure 7.)
12. Re-install the cooling duct in new
orientation. (Figure 8.)
(a) Remove the 4 screws securing the flange to
the cooling duct. Turn the flange 90
degrees so the mounting holes used to
secure the cooling duct assembly align with
the mounting holes in the side of the lamp
housing. Re-assemble the cooling duct
assembly and slide it back into position.
When the cooling duct assembly is
inserted, the wire mesh side of the cooling
duct should be facing out the rear of the
projector, away from the screen.
(b) Install the lamp housing top plate - 3
screws.
(c) Install the lamp. Tighten 4 captive screws
until the top of the lamp is flush with the
housing.
(d) Re-connect the fan harness (spade
connectors) to the fan using needle-nose
pliers.
(e) Re-connect the cables disconnected
between modules in Step 2. (Figure 9.)
Figure 5. Flip PHM
Figure 6. Install PHM
Figure 7. Tighten mounting
screws