Power Up
!
!
WARNING:
Make sure that you connect the cables between the C360 and the external power
WARNING:
supply correctly:
Positive ("+") to positive ("+")
Negative ("-") to negative ("-")
!
!
WARNING:
Asegúrese que las polaridades de los cables entre el C360 y la fuente de
ADVERTENCIA:
alimentación externa estén conectados correctamente:
3. Replace the plastic cover by aligning the holes with the screw receptacles and replacing
the two Phillips screws.

Supplemental Earthing of the C360 (Optional)

When connecting a BUPS to the C360, you must also connect a ground wire to the ground stud
provided on the rear of the unit. This ground conductor must be green/yellow, a minimum of 16
AWG and be terminated with a lug that is suitable for the M4 stud provided. The other end of the
ground conductor is to be terminated to a suitable building ground point such as a cold water
pipe.

Post-Installation

The following indicate that you have performed the installation procedure correctly:
Table 6: Post-Installation Indications
Procedure
Powering the C360
24 Quick Start for Hardware Installation: The Avaya C360 Converged Stackable Switch
Positivo ("+") a Positivo ("+")
Negativo ("-") a Negativo ("-")
Indication
All front panel function LEDs illuminate briefly.
- If the PWR LED blinks once every 1
second, then the BUPS is active and the
main PSU is down.
The LINK, SYS and PWR LEDs light
The port LEDs flash