Arbitrary shutter setting

You can set the shutter setting from a minimum of 10 µs
to a maximum of 60 s in increments of 1 CLK or 1 µs.
♦ Configuring an arbitrary shutter setting
Set three parameters with SHUTTER commands.
Parameter 1: 16
Parameter 2: Numeral in increments of 1 µs.
Parameter 3: 1/36 MHz = integer in increments of 27.78 ns 0 - 35
Setting example
Exposure time [µs]
Command
10 µs.
SHUTTER 16 10 0
31.500
SHUTTER 16 31 30
1500000
SHUTTER 16 1500000 0
60000000 (60 s)
SHUTTER 16 60000000 0
You can set an arbitrary setting in any mode other than
trigger mode.
Mode
Settable
Normal
a
Binning
a
Partial
a
Trigger
Note
Use of an arbitrary shutter may result in horizontal noise
occurring in the captured image. In such a case, you can
remove the noise by using the overlap function.
When the exposure time is set to 100 µs and below, or 2
s and above, smear and noise may appear in images.
This is not a malfunction.
(Minimum setting)
(Maximum setting)
Remark
1/15 s or less and 1/7.5 s or
more is also settable
Cannot be set in both edge
mode and width mode.
(Cannot be set in trigger
binning mode and trigger
partial scan mode as well.)
(Arbitrary shutter selection)
0 - 60000000