Binarization Setting Command; Digital Setting Command; Gamma Setting Command; Filter Setting Command - Sony XCL-U100 Technical Manual

Digital video camera module
Table of Contents

Advertisement

Each parameter delays by (setting value) × clock unit
(27.777 ns).

Binarization Setting Command

x Binarization Threshold Value Setting
[Command] BINARIZE
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
([Parameter 2]) <Binarization threshold value (240 -
3900)>
[Process] Sets the binarization mode and the
binarization threshold value.

Digital Setting Command

x Digital Gain Setting
[Command] DGAIN
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
[Parameter 2] <Gain (0.000 - 15.000)>
[Process] Sets the digital gain.
x Digital Pedestal Setting
[Command] DPEDESTAL
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
([Parameter 2]) <Pedestal level (0 - 2047)>
[Process] Sets the digital pedestal level.
x Digital Clamp Setting
[Command] DCLAMP
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
([Parameter 2]) <Clamp adjusting value (0 - 1023)>
[Process] Sets the digital clamp and the clamp adjusting
value.

Gamma Setting Command

x Gamma Correction Mode Setting
[Command] GAMMA-MODE
[Parameter 1] <Mode (0 - 5)>
0: OFF
1: Optional setting
2: Optional setting (Setting value is not saved.)
3: Default setting
4: Gamma value setting
5: Gamma value setting (Setting value not saved.)
[Process] Sets the gamma mode.
Setting gamma mode 3 initializes LUT value.
x LUT Value Setting (the case of gamma mode
1 and 2)
[Command] GAMMA
[Parameter 1] <IN data (0 - 4095)>
[Parameter 2] <OUT data (0 - 4095)>
[Process] Sets the LUT value optionally.
x LUT Value Setting (When gamma modes 4
and 5)
[Command] GAMMA
[Parameter 1] <Gamma value (0.00 - 1.00)>
([Parameter 2]) <Gamma offset value (0 - 4095)>
[Process] Sets the LUT value with a gamma value.

Filter Setting Command

x Filter Mode Setting
[Command] FILTER-MODE
[Parameter 1] <Mode (0 - 2)>
0: OFF
1: Optional setting
2: Table setting
[Process] Sets the filter mode.
x Filter Setting (the case of filter mode 1)
[Command] FILTER
[Parameter 1] <Address (11 / 12 / 13 / 21 / 22 / 23 / 31 /
32 / 33)>
[Parameter 2] <Filter factor (± 0.000 – ±10.000)>
[Process] Sets the filter optionally.
x Filter Setting (the case of filter mode 2)
[Command] FILTER
[Parameter 1] <Table pattern (1 - 6)>
[Process] Sets the filter table pattern.

Binning / Partial Setting Command

x Binning Mode Setting
[Command] BINNING
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
[Process] Sets the binning mode.
x Partial Scan Setting
[Command] PARTIAL
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
([Parameter 2]) <Read beginning point (0 - 960)>
([Parameter 3]) <Read ending point (239 - 1199)>
[Process] You can configure any position within a
minimum range of 240 lines.
x Horizontal Partial Scan Setting
[Command] HPARTIAL
[Parameter 1] <Mode (0 - 1)>
Page 35
Command Specification