Connecting The Refrigerant Pipe - Samsung MH026FKEA Installation Manual

Free joint multi air conditioner (cool and heat)
Hide thumbs Also See for MH026FKEA:
Table of Contents

Advertisement

I
I
U
NSTALLING THE
NDOOR
NIT

Connecting the Refrigerant Pipe

Refrigerant oil
Torque wrench
Flare nut
Insulation
refrigerant pipe
Gas
refrigerant
pipe
Liquid refrigerant pipe
12
E-
There are two refrigerant pipes of differing diameters:
1
Remove the pinch pipe on the pipes and connect the assembly pipes to
each pipe, tightening the nuts, first manually and then with a torque
wrench, a spanner applying the following torque.
Spanner
Union
N N
o o
N N
o o
2
Must use insulator which is thick enough to cover the refrigerant pipe to
protect the condensate water on the outside of pipe falling onto the floor
and the efficiency of the unit will be better.
Clamp
Insulation
refrigerant pipe
3
Cut off any excess foam insulation.
4
Be sure that there must be no crack or wave on the bended area.
5
It would be necessary to double the insulation thickness(10mm or more)
to prevent condensation even on the insulator when if the installed area is
warm and humid.
A smaller one for the liquid refrigerant
A larger one for the gas refrigerant
The inside of copper pipe must be clean & has no dust.
Outer Diameter
6.35 mm (1/4")
9.52 mm (3/8")
12.70 mm (1/2")
15.88 mm (5/8")
19.05 mm (3/4")
22.23 mm (7/8")
t t
e e
t t
e e
If the pipes must be shortened refer to page 13.
Torque (kgf•cm)
140~170
250~280
380~420
440~480
990~1210
990~1210