Step 6 Connecting the refrigerant pipe

◆ AJ052/068RCJ3EG
1 Piping outside diameter
Indoor unit
Out unit
AR07/09/12********,
AJ016/020/026
AJ052RCJ3EG
/035RB*DEG
AJ068RCJ3EG
AR18********,
AJ052RB*DEG
Main power switch
NOTE
• AJ052RCJ3EG Outdoor unit cannot be connected to
the following indoor unit combination.
-AJ052RBNDEG/AJ052RBMDEG
• AJ068RCJ3EG Outdoor unit cannot be connected to
the following indoor unit combination.
-AJ***RBJDEG
2 Piping length and the height
1 Room
max
length
Dimension
25m
Composition
A,B,C
Make at least one round:
It will reduce noise and vibration
Outside
Power
diameter
supply Ø,
V, Hz
Liquid Gas
3/8"
1,220-240,
1/4"
50
1/2"
(h) (H)
C
A
B
3 Room
Max height
Max height
total max
between
between
length
indoor unit
indoor units
& outdoor
unit
50m
15m
7.5m
A+B+C
(H)
(h)
◆ AJ080RCJ4EG
1 Piping outside diameter
Indoor unit
Out unit
AR07/09/12********,
AJ016/020/026
/035RB*DEG
AJ080RCJ4EG 1,220-240,
AR18********,
AJ052RB*DEG
AR24********
A
Main power switch
NOTE
• AJ080RCJ4EG Outdoor unit cannot be connected to
the following indoor unit combination.
-AJ***RBJDEG
2 Piping length and the height
1 Room
max
total max
length
Dimension
25m
Composition
A,B,C,D
A+B+C+D
Make at least one round:
It will reduce noise and vibration
Outside
Power
diameter
supply Ø,
V, Hz
Liquid Gas
3/8"
1/4"
50
1/2"
5/8"
(h) (H)
B
C
D
4 Room
Max height
Max height
between
between
length
indoor
indoor
unit &
units
outdoor
unit
70m
15m
7.5m
(H)
(h)