Typical Supervised Power Limited Notification
Appliance Circuits
Use only compatible, UL listed notification appliances (see the
Device Compatibility Document, 15378). Maximum current per
circuit is 3.0 amps, subject to the limitations of the power supply.
Style Y
4.7K, 1/2 watt ELR,
Part # 71252.
UL listed
24 VDC
Polarized Bell
UL listed
24 VDC
Polarized Horn
Notes:
1)
The Remote Station Alarm Output and the Municipal Box Output must not be used simultaneously.
2)
Notification Appliance Circuits, Remote Station Trouble output, and the Remote Station Alarm output are power limited and
may be connected to limited-energy cable.
3)
Wire Notification Appliances according to the manufacturer's instructions packaged with each device.
4)
Terminal blocks will accept #12 to #22 AWG wire.
5)
Size notification circuit wire for a maximum drop of 2 volts DC.
6)
The RS-1459 module is required when the Remote Station or Municipal Box Output is connected to a circuit that exits the
protected premises. Exception - The RS-1459 module is not required for the Municipal Box Circuit if all of the following
conditions exist: (1) wiring is in conduit, (2) wire length is less than 1000 meters, (3) wiring does not cross any power lines and
(4) must not be in the vicinity of any high voltage..
Figure 4-1: CPU Terminal Connections
24 VDC (nominal). 10 mA max rated current.
Internal resistance = 1360 ohms (nominal).
Intended for connection to the polarity reversal
circuit of a remote station receiving unit (Fire-Lite
Model RS-82) having compatible ratings.
Style Z
General
Trouble
Contacts
(power-limited source
only)
2A @ 30VDC
1A @ 120VAC
(resistive)
S200 15032 Rev C 02/22/96 P/N 15032:C
Remote Station Outputs
Non-Supervised, Power Limited
(Standby polarity shown)
Wiring can leave the building
Remote Station
Remote Station
Alarm Output
Trouble Output
General
Alarm
Contacts
(power-limited source
only)
5A @ 30VDC
5A @ 120VAC
(resistive)
Local Energy
Municipal Box
Trip current = 0.25 Amps (min)
Coil voltage = 3.65 VDC (min)
Coil resistance = 14.6 ohms (max)
Municipal box
wiring must be
run in conduit.
Municipal Box
Output
Supervised (for
open circuit)
Wiring can leave
the building
Max Current = (short circuit) = 0.6 Amps
Max Voltage = (open circuit) = 27.6 VDC
Max Wire Resistance = 5 Ohms
21