ASSEMBLY & INSTALLATION INSTRUCTIONS
2. Install the pro vid ed battery ter mi nals as shown in
Figure 4.
Battery
Terminal
12 Volt
Battery
Battery Box
Figure 4 - Battery Installations/Connections
3. To reduce the pos si bil i ty of spark ing attach the wires
to the battery in the fol low ing order. Re fer to Figure
4. First attach the red wire from the voltage reg u la tor
and the red wire from the control box to the pos i tive
"+" ter mi nal of bat tery. Next, attach the black wire
from the voltage regulator and the black wire from the
con trol box to the negative "-" terminal of the battery.
To dis con nect the battery remove the wires in the
op po site order as installed. Install bat tery box cover
and fasten in place.
INSTALLATION
Responsibility
The owner and/or user must have an un der stand ing of
the man u fac tur er's operating instructions and warn ings
be fore us ing this Hotsy pressure washer. Warn ing in for -
ma tion should be em pha sized and understood. If the
op er a tor is not fl uent in En glish, the man u fac tur er's in-
struc tions and warnings shall be read to and dis cussed
with the op er a tor in the operator's native lan guage by
the pur chas er/owner, making sure that the operator
com pre hends its contents.
Owner and/or user must study and maintain for fu ture
ref er ence the man u fac tur ers' in struc tions.
This manual should be considered a per ma nent part
of the machine and should remain with it if machine
is re sold.
When ordering parts, please specify mod el and se -
ri al number.
10
Battery
Box Lid
Black Wire From
Control Box
Black Wire
From Voltage
Regulator
Red Wire From
Control Box
Red Wire From
Box Strap
Voltage Regulator
HOTSY 965SS-1075SS • 8.914-401.0 • Rev. 09/11

Getting Started

IMPORTANT: Proper initial installation of equip ment
will assure more satisfactory per for mance, longer
service life, and lower main te nance cost.
IMPORTANT: The use of a backfl ow preventer on
the water supply hose is recommended and may be
required by local code.
The pressure washer should be run on a level sur face
and in a protected area where it is not readily infl uenced
by out side forces such as strong winds, freezing
tem per a tures, rain, etc. The pressure wash er should
be located to assure easy access for fi lling of fl uids,
adjustments and main te nance. Normal pre cau tions
should be taken by the op er a tor to pre vent moisture
from reaching the pressure washer. It is rec om mend ed
that a par ti tion be made between the wash area and the
pressure washer to prevent di rect spray from the wand
from coming in contact with the pressure washer. Moisture
reaching the equip ment will reduce the pressure washer's
service life. All installations must com ply with the local
codes covering such installations.
Venting
CAUTION: All venting must be in accordance with ap-
plicable fed er al and state laws, and local or di nanc es.
Consult local heating con trac tors .
If the pressure washer is to be used in an enclosed area,
a fl ue must be installed to vent burner and en gine exhaust
to the outside atmosphere. Be sure the fl ue is the same
size as the burner exhaust vent on the pressure washer.
See Component Identifi cation for location. Poor draft
will cause the pressure wash er to soot and not operate
properly. When selecting the location for in stal la tion,
beware of poorly ventilated lo ca tions or areas where
exhaust fans may cause an in suf fi cient supply of oxygen.
Proper combustion can only be ob tained when there is a
suffi cient supply of oxygen avail able for the amount of fuel
being burned. If it is necessary to install the machine in a
poorly ven ti lat ed area, outside fresh air may have to be
piped to the burner and a fan installed to bring suffi cient
air into the machine. Locate the pressure washer so
that the fl ue will be as straight as pos si ble and protrude
through the roof at a proper height and location to provide
adequate draft. This oil fi red pressure wash er must have
a draft regulator installed in the fl ue (avail able from most
heating contractors). A draft reg u la tor will permit prop er
upward fl ow of exhaust fl ue gases.
In addition, the pressure washer should never be operated
in an enclosed area where high ambient temperatures
ex ist. High ambient temperatures (above 100
cause engine oil failure and will greatly reduce the
engine's performance.