Mm Overlay Panel Dimensions - Monogram ZSGS420D Design And Installation Manual

Side by side refrigerators
Table of Contents

Advertisement

19 mm OVERLAY PANEL DIMENSIONS

For a more custom appearance, overlay panels may be
installed on trimmed models. The overlay panel must be
secured to a 6 mm thick backer panel which slides into the
trim. A spacer panel 3 mm thick must be placed between
the overlay and backer panel.
Assemble the panels with glue and screws.
• Center the spacer panel on the backer panel, left to right
and top to bottom. Secure the panels with glue.
• Center the spacer and backer panel on the overlay
panel and secure with glue and screws. Screws must be
countersunk into the backer panel.
IMPORTANT NOTE—Dispenser Models:
The refrigerator is supplied with two dispenser trims,
one for framed panels and one for overlay panels.
The overlay dispenser trim is designed to fit a total
panel thickness of 28 mm.
• If the panel is less than 28 mm a noticeable gap
may be created around the dispenser trim.
• If the panel is more than 28 mm the dispenser
trim cannot be secured to the door.
See Dispenser Trim Fit Example, page 9.
A
Grille Panel
F
Dispenser
Cutout
G
Freezer
Fresh Food
Panel
Panel
D
E
IMPORTANT NOTE: Maximum
total weight for the assembled
panels:
• Fresh food door panel – 34 kg
• Freezer door panel – 24 kg
• Grille Panel – 8 kg
Design Guide
Dispenser Cutout
B
391 mm
244 mm
C
42" Side-by-Side (in millimeters)
6 mm Backer Panel
3 mm Spacer Panel
19 mm Overlay Panel 1019 mm
Door
6 mm
Backer
Panel
6 mm + 3 mm + 19 mm = 28 mm Total Panel Thickness
• The overlay panel must be constructed according to
the specifications shown to achieve the correct total
thickness.
• Alternative panel construction methods such as
securing a 19 mm panel to a 6 mm backer panel
cannot be used. Another method, routing a 19 mm
thick panel on all sides cannot be used. These
methods will not result in the required 28 mm
panel thickness.
When a raised panel design is to be used, a custom
middle rail is required. See page 9 for details.
*Cut the dispenser opening after the backer, spacer and overlay
panels have been assembled.
A
B
C
1013 mm
241 mm
1737 mm
991 mm
219 mm
1702 mm
248 mm
1743 mm
8
Overlay Panel
19 mm
Spacer Panel
Overlay
Panel
Backer Panel
NOTE: Left-to-right offset
is not always equal to
3 mm
top-to-bottom offset.
Spacer
*Dispenser
Cutout Position
D
E
F
370 mm
624 mm
337 mm
591 mm
376 mm
630 mm
456 mm
G
83 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zsgb420dZsgw420d

Table of Contents