RHINO Power Pack series Operation Manual page 19

Turbine engines
Table of Contents

Advertisement

 
 
All the parameters in the submenus are factory preadjusted and are a good starting point to
fine tunning your engine. Note: Only make small changes at one time when adjusting the
turbine parameters.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
still get "Ignition fail" alarm, increase this value one point at a time until it creates a sufficient
temperature change to pass to next step.
 
 
 
 
 
 
 
 
 
 
4.5 Start Submenu.
When selecting the "Start" submenu the Startup Parameters
screen is displayed.
The next screen is activated by pressing the "menu up"
button will display "Pump Pw. Ignt. K".
Entries are numeric values between 000 and 255
This is the only fuel adjustment you have in Kerostart mode
but it is most critical.
A value that is too low will probably get the fuel ignited but it
will not raise the temperature enough to trigger the preheat
mode, so if you hear or see flames inside the turbine but you
When selecting the menu up button the "Glow plug
power" screen is displayed.
With the Data up and Data down buttons you can change
this value. The value is programmed as a voltage. The
idea is to have the lowest possible value that will ignite
the gas to conserve battery power. Default value is 5.5V;
values can be changed in 0.1 volt increments.
Next is the "Low Batt. Volts", this is minimum voltage that the
battery can drop during the start up without trigging the "Low
Battery" alarm, If it's adjusted too low it can provoke hot or
failed starts, too high and it will only allow a couple of start
ups
19