Determine Installa on Loca on 
You must ensure that clearances will be met and that 
the vent length will be within required limits.  
Consider the installa on environment, water quality, 
and need for freeze protec on.  Requirements for the 
gas line, water lines, electrical connec on, and 
condensate disposal can be found in their respec ve 
installa on sec ons of this manual. 
Water Quality 
Considera on of care for your water heater should  
include evalua on of water quality.   
Water that contains chemicals exceeding the levels 
below affect and damage the heat exchanger.  
Replacement of the heat exchanger due to water 
quality damage is not covered by the warranty. 
 
Total Hardness 
Aluminum * 
Chlorides * 
Copper * 
Iron * 
Manganese * 
pH * 
TDS (Total Dissolved 
Solids) * 
Zinc * 
* Source: Part 143 Na onal Secondary Drinking Water 
Regula ons 
If you install this water heater in an area that is 
known to have hard water or that causes scale build‐
up the water must be treated and/or the heat 
exchanger flushed regularly. 
When scale build‐up in the heat exchanger begins to 
affect the performance of the water heater, a 
diagnos c code "LC#" will display.  Flush the heat 
exchanger to prevent damage to it.  Scale build up is 
caused by hard water set at a high temperature.   
Rinnai provides a "Scale Control System" that offers 
superior lime scale preven on and corrosion control 
by feeding a blend of control compounds into the 
water supply. 
Maximum Level 
Up to 200 mg / L 
Up to 0.2 mg / L 
Up to 250 mg / L 
Up to 1.0 mg / L 
Up to 0.3 mg / L 
Up to 0.05 mg / L 
6.5 to 8.5 
Up to 500 mg / L 
Up to 5 mg / L 
Value Series Manual 
Environment 
Air surrounding the water heater, ven ng, and vent 
termina on(s) is used for combus on and must be 
free of any compounds that cause corrosion of 
internal components.  These include corrosive 
compounds that are found in aerosol sprays, 
detergents, bleaches, cleaning solvents, oil based 
paints/ varnishes, and refrigerants.  The air in beauty 
shops, dry cleaning stores, photo processing labs, and 
storage areas for pool supplies o en contains these 
compounds.  Therefore it is recommended that 
outdoor models be used for these loca ons where 
possible. 
The water heater, ven ng, and vent termina on(s)  
should not be installed in any areas where the air may 
contain these corrosive compounds.  If it is necessary 
for a water heater to be located in areas which may 
contain corrosive compounds, the following 
instruc ons are strongly recommended. 
IMPORTANT CONSIDERATIONS FOR: 
  Indoor/Internal Water Heaters 
DO NOT Install in areas where air for combus on 
can be contaminated with chemicals. 
Before installa on, consider where air has the 
ability to travel within the building to the water 
heater. 
Where possible, install the water heater in a 
sealed closet so that it is protected from the 
poten al of contaminated indoor air. 
Chemicals that are corrosive in nature should not 
be stored or used near the water heater. 
  Outdoor/External Water Heaters and Vent 
Termina ons of Indoor/Internal Water Heaters 
Install the water heater as far away as possible 
from exhaust vent hoods. 
Install as far away as possible from air inlet 
vents.  Corrosive fumes may be released through 
these vents when air is not being brought in 
through them. 
Chemicals that are corrosive in nature should not 
be stored or used near the water heater or vent 
termina on. 
Damage and repair due to corrosive compounds in 
the air is not covered by warranty. 