Vent Termina on Clearances 
For indoor models, you must install a vent termina on to bring in combus on air and expel exhaust. 
TERMINATION
Clearance in
Ref. A also
applies to
anticipated
snow line
SNOW
D
E
B
L
Ref 
Clearance above grade, veranda, porch, deck, or balcony 
Clearance to window or door that may be opened 
Clearance to permanently closed window 
Ver cal clearance to ven lated soffit, located above the terminal within a 
horizontal distance of 2 feet (61 cm) from the center line of the terminal 
Clearance to unven lated soffit 
Clearance to outside corner 
Clearance to inside corner 
Clearance to each side of center line extended above meter/regulator 
assembly 
Clearance to service regulator vent outlet 
Clearance to nonmechanical air supply inlet to building or the combus on 
air inlet to any other appliance 
Clearance to a mechanical air supply inlet 
Clearance above paved sidewalk or paved driveway located on public 
property 
Clearance under veranda, porch, deck, or balcony  
[1]  A vent shall not terminate directly above a sidewalk or paved driveway 
that is located between two single family dwellings and serves both 
dwellings. 
[2]  Permi ed only if veranda, porch, deck, or balcony is fully open on a 
minimum of two sides beneath the floor. 
 
INSIDE
CORNER DETAIL
G
A
C
FIXED
CLOSED
OPERABLE
F
B
Descrip on 
Value Series Manual 
H
B
FIXED
B
CLOSED
OPERABLE
B
J
B
A
Canadian Installa ons 
12 inches (30 cm) 
36 inches (91 cm) 
3 feet (91 cm) within a height 15 
feet (4.5 m) above the meter/
regulator assembly 
36 inches (91 cm) 
36 inches (91 cm) 
6 feet (1.83 m) 
7 feet (2.13 m) 1 
12 inches (30 cm) 2  
For clearances not specified in ANSI Z223.1/NFPA 54, clearances are in 
accordance with local installa on codes and the requirements of the gas 
supplier. 
  Clearance to opposite wall is 24 inches (60 cm). 
I
M
K
X
AIR SUPPLY INLET 
V
VENT TERMINAL 
AREA WHERE TERMINAL 
IS NOT PERMITTTED 
US Installa ons 
12 inches (30 cm) 
12 inches (30 cm) 
12 inches (30 cm) 
3 feet (91 cm) above if within 10 
feet (3 m) horizontally 