The appliance must be inspected annually by a licensed professional.  Repairs and maintenance should be per‐
formed by a licensed professional.  The licensed professional must verify proper opera on a er servicing. 
WARNING
To protect yourself from harm, before performing maintenance: 
Turn off the electrical power supply by unplugging the power cord or by turning off the electricity at the 
circuit breaker.  (The temperature controller does not control the electrical power.) 
Turn off the gas at the manual gas valve, usually located immediately below the water heater. 
Turn off the incoming water supply.  This can be done at the isola on valve immediately below the water 
heater or by turning off the water supply to the building. 
WARNING
The following maintenance items are required for the proper opera on of your water heater. 
The appliance must be inspected annually by a 
licensed professional.  Repairs and maintenance 
should be performed by a licensed professional.  The 
licensed professional must verify proper opera on 
a er servicing. 
Cleaning 
It is impera ve that control compartments, burners, 
and circula ng air passageways of the appliance be 
kept clean. 
Clean as follows: 
1.  Turn off and disconnect electrical power.  Allow to 
cool. 
2.  Close the water shut off valves.  Remove and clean 
the water inlet filter. 
3.  Remove the front panel by removing 4 screws.   
4.  Use pressurized air to remove dust from the main 
burner, heat exchanger, and fan blades.  Do not 
use a wet cloth or spray cleaners on the burner.  
Do not use vola le substances such as benzene 
and thinners.  They may ignite or fade the paint. 
5.  Use so  dry cloth to wipe cabinet.   
Vent System 
The vent system should be inspected at least annually 
for blockages or damage.  If the vent is blocked 
contact a licensed professional. 
36 
Required Maintenance 
Keep the appliance area clear and free from combus ble materials, gasoline, and other 
flammable vapors and liquids. 
Motors 
Motors are permanently lubricated and do not need 
periodic lubrica on.  However you must keep fan and 
motor free of dust and dirt by cleaning annually. 
Temperature Controller 
Use a so  damp cloth to clean the temperature 
controller.  Do not use solvents. 
Lime / Scale Build‐up 
If you receive diagnos c code "LC#" (LC1, LC2,...), 
refer to the procedure, Flushing the Heat Exchanger.  
Refer to the sec on on Water Quality to see if your 
water needs to be treated or condi oned.  (When 
checking maintenance code history, "00" is 
subs tuted for "LC#".) 
Snow Accumula on 
Keep the area around flue terminal free of snow and 
ice.  The appliance will not func on properly if the 
intake air or exhaust is impeded (blocked or par ally 
blocked) by obstruc ons.   
Clean the water filter 
Clean the inlet water filter by closing the cold and hot 
water inlet isola on (shut‐off) valves.  Put a bucket 
under the filter at the bo om of the water heater to 
catch any water that is contained inside the unit.  
Unscrew the water filter.  Rinse the filter to remove 
any debris.  Install the filter and open the isola on 
valves. 